Contrast-detail analysis for detection and characterization with near-infrared diffuse tomography.

B W Pogue1, C Willscher, T O McBride, U L Osterberg, K D Paulsen.   

Abstract

Near-infrared (NIR) diffuse tomography is emerging as a medical imaging modality for obtaining information related to tissue hemoglobin concentration and oxygen saturation and may be used for characterizing diseased tissues such as breast cancer. The optimal methodology for NIR image reconstruction remains an ongoing research problem with several new approaches being demonstrated in recent years. However, a comparison of reconstruction methods is problematic because tools for the objective assessment of image quality have yet to be clearly defined for this type of nonlinear reconstruction problem. Contrast-detail analysis has become an accepted assessment tool to quantify x-ray mammography image quality, and in this study it has been applied to a prototype NIR diffuse tomography system that is being evaluated for breast cancer characterization. The minimum detectable levels of contrast have been defined for different sizes of objects, and the minimum contrasts which can be accurately reconstructed have also been determined for the same object sizes. In general, objects 8 mm and larger in diameter can be accurately reconstructed and detected for most absorption contrasts which are observed in human tissues (i.e., greater than 1% contrast in absorption). Objects as small as 2 mm can be detected with high contrast (i.e., near 100%), but cannot be accurately reconstructed. Within the size range of 2 mm to 8 mm, there is an inverse correlation between contrast and detail size which is characteristic of the total noise in the system. This analysis provides an objective method for assessing detection and characterization limits and can be applied to future improvements in hardware system architecture as well as reconstruction algorithms.

Entities:  

Mesh:

Year:  2000        PMID: 11190952     DOI: 10.1118/1.1323984

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  A simulation study of the variability of indocyanine green kinetics and using structural a priori information in dynamic contrast enhanced diffuse optical tomography (DCE-DOT).

Authors:  Mehmet Burcin Unlu; Ozlem Birgul; Gultekin Gulsen
Journal:  Phys Med Biol       Date:  2008-05-27       Impact factor: 3.609

2.  Dose and detectability improvements with high energy phase sensitive x-ray imaging in comparison to low energy conventional imaging.

Authors:  Molly Donovan Wong; Aimin Yan; Muhammad Ghani; Yuhua Li; Laurie Fajardo; Xizeng Wu; Hong Liu
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

3.  Image quality and dose efficiency of high energy phase sensitive x-ray imaging: phantom studies.

Authors:  Molly Donovan Wong; Xizeng Wu; Hong Liu
Journal:  J Xray Sci Technol       Date:  2014       Impact factor: 1.535

Review 4.  Radiologic and near-infrared/optical spectroscopic imaging: where is the synergy?

Authors:  Brian W Pogue; Frederic Leblond; Venkataramanan Krishnaswamy; Keith D Paulsen
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

5.  Nanoshell-mediated near-infrared thermal therapy of tumors under magnetic resonance guidance.

Authors:  L R Hirsch; R J Stafford; J A Bankson; S R Sershen; B Rivera; R E Price; J D Hazle; N J Halas; J L West
Journal:  Proc Natl Acad Sci U S A       Date:  2003-11-03       Impact factor: 11.205

Review 6.  Nanomedicine--challenge and perspectives.

Authors:  Kristina Riehemann; Stefan W Schneider; Thomas A Luger; Biana Godin; Mauro Ferrari; Harald Fuchs
Journal:  Angew Chem Int Ed Engl       Date:  2009       Impact factor: 15.336

7.  Information content of data types in time-domain optical tomography.

Authors:  Angel R Pineda; Martin Schweiger; Simon R Arridge; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2006-12       Impact factor: 2.129

8.  A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions.

Authors:  Ronald X Xu; Donn C Young; Jimmy J Mao; Stephen P Povoski
Journal:  Breast Cancer Res       Date:  2007       Impact factor: 6.466

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.