Literature DB >> 11180907

Optimizing femoral anteversion and offset after total hip arthroplasty, using a modular femoral neck system: an experimental study.

T Sakai1, N Sugano, T Nishii, K Haraguchi, T Ochi, K Ohzono.   

Abstract

To investigate the effectiveness of a modular femoral neck system, consisting of two neutral and four types of retroverted necks for the correction of femoral anteversion and offset in total hip arthroplasty, an experimental study was carried out, using sawbones with four different angles of femoral anteversion (16 degrees, 34 degrees, 47 degrees, and 59 degrees ). With the neutral neck, reconstruction of the preoperative anteversion and offset in the normal femur was achieved. While the 15 degrees retroverted long neck was effective for the mildly or moderately anteverted femur, this retroverted neck showed insufficient correction for the severely anteverted femur. This modular neck system proved to be useful for correction of the medial component of femoral offset in femora with anteversion of less than 47 degrees. For patients with greater anteversion, a feature which is rarely seen in the clinical situation, femoral necks with a greater degree of retroversion may be useful.

Entities:  

Mesh:

Year:  2000        PMID: 11180907     DOI: 10.1007/s007760070028

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  6 in total

1.  Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty.

Authors:  Glen A Turley; Damian R Griffin; Mark A Williams
Journal:  Med Biol Eng Comput       Date:  2014-06-27       Impact factor: 2.602

2.  [Change of offset after implantation of hip alloarthroplasties].

Authors:  J Jerosch; S Funken
Journal:  Unfallchirurg       Date:  2004-06       Impact factor: 1.000

3.  Evaluation of range of motion restriction within the hip joint.

Authors:  Glen A Turley; Mark A Williams; Richard M Wellings; Damian R Griffin
Journal:  Med Biol Eng Comput       Date:  2012-12-22       Impact factor: 2.602

4.  Validation of the femoral anteversion measurement method used in imageless navigation.

Authors:  Glen A Turley; Shahbaz M Y Ahmed; Mark A Williams; Damian R Griffin
Journal:  Comput Aided Surg       Date:  2012-06-08

5.  Integrative Analysis of MicroRNA and mRNA Sequencing Data Identifies Novel Candidate Genes and Pathways for Developmental Dysplasia of Hip.

Authors:  Bolun Cheng; Yumeng Jia; Yan Wen; Weikun Hou; Ke Xu; Chujun Liang; Shiqiang Cheng; Li Liu; Xiaomeng Chu; Jing Ye; Yao Yao; Feng Zhang; Peng Xu
Journal:  Cartilage       Date:  2021-02-01       Impact factor: 3.117

6.  Total hip arthroplasty with modular stem for Crowe I and II developmental dysplasia of the hip.

Authors:  Xiangpeng Kong; Yunming Sun; Minzhi Yang; Yonggang Zhou; Jiying Chen; Wei Chai; Yan Wang
Journal:  J Orthop Surg Res       Date:  2019-11-13       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.