Abstract

Of 38 Miller/Galante-I total knee prostheses implanted between 1987 and 1990, 20 (53%) were revised. Failed metal-backed patella (15 knees; 40%) was the most frequent reason for revision. In most patients, the components were found well fixed to bone. The purpose of this study was to describe the revision technique we used for failed metal-backed patella. Total revision of all components would be ideal. However, removal of all components results in large bone loss, large blood loss, and a longer operation time. Because of the patients' relatively old age (78.7 years), less demanding activities of daily life (ADL), and the lower body weight of the Japanese patient, we chose a less invasive approach. The revision technique had the following features: (1) the grooved femoral component was not replaced, (2) the failed patellar component was replaced by an all-polyethylene patella, (3) synovectomy was performed, and (4) realignment of patellar tracking was done by lateral release and medial imbrication of the quadriceps mechanism. The mean follow-up after revision was 2 years, 4 months, and good short-term results were obtained. This less invasive approach would be beneficial for elderly patients whose ADL are less demanding.

Entities:  

Mesh:

Year:  2000        PMID: 11180899     DOI: 10.1007/s007760070020

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  1 in total

1.  Isolated all-polyethylene patellar revisions for metal-backed patellar failure.

Authors:  Ryan M Garcia; Matthew J Kraay; Victor M Goldberg
Journal:  Clin Orthop Relat Res       Date:  2008-08-08       Impact factor: 4.176

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.