Literature DB >> 11180436

Two-step navigatorless correction algorithm for radial k-space MRI acquisitions.

A Shankaranarayanan1, M Wendt, J S Lewin, J L Duerk.   

Abstract

A new way to correct magnetic resonance image artifacts resulting from view-dependent phase variations and view-dependent variations in rigid body object translation is presented by exploiting basic properties of the trajectory of radial k-space acquisitions. Simulations, phantom studies, and in vivo experiments are used to demonstrate the feasibility and the utility of this method. While somewhat analogous to navigator echo correction, in which special gradients are interleaved into the imaging sequence so echoes at the center of k-space can be acquired prior to or after collection of the image data, the current method does not require additional new gradient structures within the pulse sequence or increases in scan time. The new method uses the phase information from all collected radial k-space data points rather than only the navigator echo, which permits correction of multiple sources of view-dependent phase variation in the image data. The resultant effect is improved image quality in radial MRI acquisitions. Magn Reson Med 45:277-288, 2001. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11180436     DOI: 10.1002/1522-2594(200102)45:2<277::aid-mrm1037>3.0.co;2-1

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Intrinsic detection of motion in segmented sequences.

Authors:  Jason Mendes; Dennis L Parker
Journal:  Magn Reson Med       Date:  2010-11-03       Impact factor: 4.668

Review 2.  Motion correction in MRI of the brain.

Authors:  F Godenschweger; U Kägebein; D Stucht; U Yarach; A Sciarra; R Yakupov; F Lüsebrink; P Schulze; O Speck
Journal:  Phys Med Biol       Date:  2016-02-11       Impact factor: 3.609

3.  Continuously moving table MRI with golden angle radial sampling.

Authors:  Saikat Sengupta; David S Smith; E Brian Welch
Journal:  Magn Reson Med       Date:  2014-12-02       Impact factor: 4.668

4.  Magnetic resonance angiography of fetal vasculature at 3.0 T.

Authors:  Jaladhar Neelavalli; Uday Krishnamurthy; Pavan K Jella; Swati S Mody; Brijesh K Yadav; Kelly Hendershot; Edgar Hernandez-Andrade; Lami Yeo; Maria D Cabrera; Ewart M Haacke; Sonia S Hassan; Roberto Romero
Journal:  Eur Radiol       Date:  2016-05-17       Impact factor: 5.315

5.  Multi-slice MRI with the dynamic multi-coil technique.

Authors:  Christoph Juchem; Omar M Nahhass; Terence W Nixon; Robin A de Graaf
Journal:  NMR Biomed       Date:  2015-09-30       Impact factor: 4.044

6.  Acceleration and motion-correction techniques for high-resolution intravascular MRI.

Authors:  Shashank Sathyanarayana Hegde; Yi Zhang; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2014-08-27       Impact factor: 4.668

7.  Motion-insensitive carotid intraplaque hemorrhage imaging using 3D inversion recovery preparation stack of stars (IR-prep SOS) technique.

Authors:  Seong-Eun Kim; John A Roberts; Laura B Eisenmenger; Booth W Aldred; Osama Jamil; Bradley D Bolster; Xiaoming Bi; Dennis L Parker; Gerald S Treiman; J Scott McNally
Journal:  J Magn Reson Imaging       Date:  2016-07-07       Impact factor: 4.813

  7 in total