Literature DB >> 11175074

Improvement in Endocardial Border Delineation Using Tissue Harmonic Imaging.

Harald Becher1, Klaus Tiemann, Thomas Schlosser, Christoph Pohl, Navin C. Nanda, Michalakis A. Averkiou, Jeff Powers, Berndt Lüderitz.   

Abstract

BACKGROUND AND METHODS: For years, tissue has been assumed to be a linear medium in diagnostic ultrasound applications; thus, no backscattered signals in the second harmonic band are expected in harmonic imaging without the injection of a contrast agent. However, it has been shown that a useful tissue image is formed even without a contrast agent. The aim of this study was to evaluate whether this tissue harmonic image provided improved visualization of endocardial borders. Fifty-six adult patients with various heart diseases were investigated using conventional two-dimensional echocardiography and tissue harmonic imaging. In 30 of these patients, the left ventricular endocardial borders were well defined in the standard parasternal and apical views using conventional two-dimensional echocardiography. In the remaining 26 patients, delineation of endocardial borders was not possible in at least two segments. The equipment used was an ATL HDI-3000 diagnostic system equipped with harmonic imaging.
RESULTS: In all 56 patients, the myocardium and valves could be imaged with tissue harmonic imaging. Harmonic recordings were sharper and contained fewer clutter artifacts than conventional recordings. Most striking was the enhancement of left ventricular endocardial borders. In the 26 patients with incomplete delineation of left ventricular endocardial borders, wall motion could be evaluated in 290 of 312 (93%) segments with tissue harmonic imaging compared with only 168 of 312 (54%) segments with conventional echocardiography (P < 0.001).
CONCLUSIONS: Tissue harmonic imaging improves image quality and can be used to enhance the definition of left ventricular endocardial borders. These findings can be explained by the nonlinear propagation of ultrasound within the tissue, which results in distortion of the transmitted signal and, thus, harmonic generation.

Entities:  

Year:  1998        PMID: 11175074     DOI: 10.1111/j.1540-8175.1998.tb00642.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  8 in total

1.  Ultrasonic multipath and beamforming clutter reduction: a chirp model approach.

Authors:  Brett Byram; Marko Jakovljevic
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-03       Impact factor: 2.725

2.  Non-contrast second harmonic imaging improves interobserver agreement and accuracy of dobutamine stress echocardiography in patients with impaired image quality.

Authors:  A Franke; R Hoffmann; H P Kühl; W Lepper; O A Breithardt; M Schormann; P Hanrath
Journal:  Heart       Date:  2000-02       Impact factor: 5.994

3.  Effect of Transmit Beamforming on Clutter Levels in Transthoracic Echocardiography.

Authors:  Vaibhav Kakkad; Melissa LeFevre; Kingshuk Roy Choudhury; Joseph Kisslo; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2018-04-21       Impact factor: 1.578

Review 4.  [Improved endocardium imaging using modified transthoracic echocardiography with the second harmonic frequency (tissue harmonic imaging)].

Authors:  H Becher; K Tiemann
Journal:  Herz       Date:  1998-12       Impact factor: 1.443

5.  Short-lag spatial coherence imaging of cardiac ultrasound data: initial clinical results.

Authors:  Muyinatu A Lediju Bell; Robi Goswami; Joseph A Kisslo; Jeremy J Dahl; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2013-08-09       Impact factor: 2.998

6.  [Diagnostics and therapy of ischemia in chronic stable angina pectoris. Role of echocardiography].

Authors:  R S von Bardeleben; K Tiemann
Journal:  Herz       Date:  2013-06       Impact factor: 1.443

7.  A model and regularization scheme for ultrasonic beamforming clutter reduction.

Authors:  Brett Byram; Kazuyuki Dei; Jaime Tierney; Douglas Dumont
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-11       Impact factor: 2.725

Review 8.  Advances in ultrasonography: image formation and quality assessment.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2021-10-20       Impact factor: 1.314

  8 in total