Literature DB >> 11174925

Stimulated Acoustic Emission Nonbackscatter Contrast Effect of Microbubbles Seen with Harmonic Power Doppler Imaging.

Klaus Tiemann1, Harald Becher, Dieter Bimmel, Reinhard Schlief, Navin C. Nanda.   

Abstract

Transient imaging has been introduced to enhance the signal intensities when using echo contrast agents. However, this phenomenon is not clearly understood. To evaluate the mechanisms of this phenomenon, isolated pig hearts were investigated with different echo imaging techniques in the beating, working heart as well as in an asystolic state without any motion of the heart. The hearts of five German farm pigs (21 +/- 2.5 kg) were surgically explanted and inserted in an artificial circulation providing physiological flow and pressures. Levovist in the dosage of 0.05-0.3 g was injected into the left atrium and contrast effects evaluated in the left ventricular (LV) cavity and in the myocardium with an ultrasound imager (ATL, HDI 3000) equipped with a prototype software for harmonic imaging. Harmonic B-scans and power Doppler registrations were performed with continuous and intermittent recordings (ECG triggered at end-systole) in the beating heart and using an external trigger in the asystolic heart in which perfusion was interrupted for 20 seconds. In the beating pig heart, transient harmonic power Doppler imaging provided intensive opacification of the LV cavity and visible myocardial uptake when ECG triggering was performed. In the asystolic pig heart, with uninterrupted perfusion, both triggered and nontriggered registrations showed contrast signals in the LV cavity and in the myocardium. These findings cannot be explained with the known physics of ultrasound contrast media. Stimulated acoustic emission occurring during disintegration of the microbubbles in the acoustic field would explain this phenomenon, which has not yet been described for Levovist.

Entities:  

Year:  1997        PMID: 11174925     DOI: 10.1111/j.1540-8175.1997.tb00692.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  6 in total

1.  Assessment of myocardial perfusion abnormalities by intravenous myocardial contrast echocardiography with harmonic power Doppler imaging: comparison with positron emission tomography.

Authors:  T Muro; T Hozumi; H Watanabe; H Yamagishi; M Yoshiyama; K Takeuchi; J Yoshikawa
Journal:  Heart       Date:  2003-02       Impact factor: 5.994

2.  Potential pitfalls of visualization of myocardial perfusion by myocardial contrast echocardiography with harmonic gray scale B-mode and power Doppler imaging.

Authors:  Hisashi Masugata; Kazushi Yukiiri; Yuichiro Takagi; Koji Ohmori; Katsufumi Mizushige; Masakazu Kohno
Journal:  Int J Cardiovasc Imaging       Date:  2004-04       Impact factor: 2.357

3.  Effect of power Doppler and digital subtraction techniques on the comparison of myocardial contrast echocardiography with SPECT.

Authors:  B Haluska; C Case; L Short; J Anderson; T H Marwick
Journal:  Heart       Date:  2001-05       Impact factor: 5.994

4.  Post-dive ultrasound detection of gas in the liver of rats and scuba divers.

Authors:  Antonio L'abbate; Claudio Marabotti; Claudia Kusmic; Antonino Pagliazzo; Alessandro Navari; Vincenzo Positano; Mario Palermo; Antonio Benassi; Remo Bedini
Journal:  Eur J Appl Physiol       Date:  2011-02-12       Impact factor: 3.078

5.  Hard shell gas-filled contrast enhancement particles for colour Doppler ultrasound imaging of tumors.

Authors:  H Paul Martinez; Yuko Kono; Sarah L Blair; Sergio Sandoval; Jessica Wang-Rodriguez; Robert F Mattrey; Andrew C Kummel; William C Trogler
Journal:  Medchemcomm       Date:  2010-10       Impact factor: 3.597

Review 6.  [Improved endocardium imaging using modified transthoracic echocardiography with the second harmonic frequency (tissue harmonic imaging)].

Authors:  H Becher; K Tiemann
Journal:  Herz       Date:  1998-12       Impact factor: 1.443

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.