Literature DB >> 11174825

The AneuRx stent graft: four-year results and worldwide experience 2000.

C K Zarins1, R A White, F L Moll, T Crabtree, D A Bloch, K J Hodgson, M F Fillinger, T J Fogarty.   

Abstract

OBJECTIVE: The objective was to review the current results of endovascular abdominal aortic aneurysm repair with the AneuRx stent graft and to determine the effectiveness of the device in achieving the primary objective of preventing aneurysm rupture.
METHODS: The outcome of all patients treated during the past 4 years in the U.S. AneuRx clinical trial was determined, and the worldwide clinical experience was reviewed.
RESULTS: A total of 1192 patients were treated with the AneuRx stent graft during all phases of the U.S. Clinical Trial from June 1996 to November 1999, with follow-up extending to June 2000. Ten (0.8%) patients have had aneurysm rupture, with most ruptures (n = 6) occurring in 174 (3.4%) patients treated with an early stiff bifurcation stent graft design used in phase I and in the initial stages of phase II. Since the current, flexible, segmented bifurcation stent graft design was introduced, four (0.4%) ruptures have occurred among 1018 patients treated. Of these, one was during implantation, two were placed too far below the renal arteries, and one patient refused treatment of a type I endoleak. Kaplan-Meier analysis of all 1192 patients treated with the AneuRx stent graft including both stent graft designs revealed the patient survival rate to be 93% at 1 year, 88% at 2 years, and 86% at 3 years, freedom from conversion to open repair to be 98% at 1 year, 97% at 2 years, and 93% at 3 years, and freedom from secondary procedure to be 94% at 1 year, 92% at 2 years, and 88% at 3 years. Freedom from aneurysm rupture with the commercially available segmented bifurcation stent graft was 99.7% at 1 year, 99.5% at 2 years, and 99.5% at 3 years. The presence or absence of endoleak on contrast computed tomography scanning after stent graft placement was not found to be a significant predictor of long-term outcome measures. Worldwide experience with the AneuRx device now approaches 10,000 patients.
CONCLUSIONS: Endovascular management of abdominal aortic aneurysms with the AneuRx stent graft has markedly reduced the risk of aneurysm rupture while eliminating the need for open aneurysm surgery in 98% of patients at 1 year and 93% of patients at 3 years. The device was effective in preventing aneurysm rupture in 99.5% of patients over a 3-year period. The overall patient survival rate was 93% at 1 year and 86% at 3 years.

Entities:  

Mesh:

Year:  2001        PMID: 11174825     DOI: 10.1067/mva.2001.111676

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  11 in total

1.  Increasing incidence of midterm and long-term complications after endovascular graft repair of abdominal aortic aneurysms: a note of caution based on a 9-year experience.

Authors:  T Ohki; F J Veith; P Shaw; E Lipsitz; W D Suggs; R A Wain; M Bade; M Mehta; N Cayne; J Cynamon; J Valldares; J McKay
Journal:  Ann Surg       Date:  2001-09       Impact factor: 12.969

2.  Implementation of a successful endovascular surgical program in a non-teaching tertiary-care centre in Ontario.

Authors:  Rod P N Willoughby; John A Fenton; Santosh R Pudupakkam; Robert A Greco; Evan W D Roberts; Guy DeRose; Stewart Kribs
Journal:  Can J Surg       Date:  2004-06       Impact factor: 2.089

3.  Mathematical Model analysis of Wallstent and Aneurx: dynamic responses of bare-metal endoprosthesis compared with those of stent-graft.

Authors:  Suncica Canic; K Ravi-Chandar; Zvonimir Krajcer; Dragan Mirkovic; Serguei Lapin
Journal:  Tex Heart Inst J       Date:  2005

4.  Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine.

Authors:  Venkatesh K Raman; Parag V Karmarkar; Michael A Guttman; Alexander J Dick; Dana C Peters; Cengizhan Ozturk; Breno S S Pessanha; Richard B Thompson; Amish N Raval; Ranil DeSilva; Ronnier J Aviles; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  J Am Coll Cardiol       Date:  2005-06-21       Impact factor: 24.094

5.  Abdominal aortic aneurysm (AAA): cost-effectiveness of screening, surveillance of intermediate-sized AAA, and management of symptomatic AAA.

Authors:  Marc D Silverstein; Stephen R Pitts; Elliot L Chaikof; David J Ballard
Journal:  Proc (Bayl Univ Med Cent)       Date:  2005-10

6.  Endoluminal graft repair for abdominal aortic aneurysms in high-risk patients and octogenarians: is it better than open repair?

Authors:  G A Sicard; B G Rubin; L A Sanchez; C A Keller; M W Flye; D Picus; D Hovsepian; E T Choi; P J Geraghty; R W Thompson
Journal:  Ann Surg       Date:  2001-10       Impact factor: 12.969

7.  Concomitant pulmonary carcinoma and abdominal aortic aneurysm: therapeutic strategies.

Authors:  Giuseppe Borzellino; Francesco Giovinazzo; Anna Maria Minicozzi; Roberto Dusi; Leonardo Politi; Gian Franco Veraldi
Journal:  Surg Today       Date:  2008-05-31       Impact factor: 2.549

8.  Endovascular stent graft repair of abdominal and thoracic aortic aneurysms: a ten-year experience with 817 patients.

Authors:  Michael L Marin; Larry H Hollier; Sharif H Ellozy; David Spielvogel; Harold Mitty; Randall Griepp; Robert A Lookstein; Alfio Carroccio; Nicholas J Morrissey; Victoria J Teodorescu; Tikva S Jacobs; Michael E Minor; Claudie M Sheahan; Kristina Chae; Juliana Oak; Andrew Cha
Journal:  Ann Surg       Date:  2003-10       Impact factor: 12.969

9.  Changes in suprarenal and infrarenal aortic angles after endovascular aneurysm repair.

Authors:  Ho Kyun Lee; Sang Young Chung; Jea Kyu Kim; Sung Hee Yoo; Soo Jin Na Choi
Journal:  Ann Surg Treat Res       Date:  2014-09-25       Impact factor: 1.859

10.  Endovascular repair of abdominal aortic aneurysm: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2002-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.