Literature DB >> 11174538

Comparison of bond strength of three adhesives: composite resin, hybrid GIC, and glass-filled GIC.

D Rix1, T F Foley, A Mamandras.   

Abstract

The objective of this study was to compare 3 orthodontic adhesives in the areas of shear-peel bond strength, location of adhesive failure, and extent of enamel cracking before bonding and after debonding of orthodontic brackets. The adhesives included a composite resin control (Transbond XT; 3M/Unitek, St Paul, Minn), a resin-modified glass ionomer cement (Fuji Ortho LC; GC America Corp, Alsip, Ill), and a polyacid-modified composite resin under dry and saliva-contaminated conditions (Assure; Reliance Orthodontic Products Inc, Itasca, Ill). Metal brackets were bonded to the buccal surfaces of 160 (4 groups of 40) human premolars. The bonded teeth were stored in deionized water at 37 degrees C for 30 days and thermocycled for 24 hours before debonding with a Universal Instron (Instron Corp, Canton, Mass) testing machine. The extent of cracking in the buccal surfaces was evaluated under 16x magnification before bonding and after debonding. Although the bond strength of the composite resin control (20.19 MPa) was significantly greater (P <.05) than that of the adhesives in the other groups, clinically acceptable shear-peel bond strengths were found for all adhesives (Fuji Ortho LC = 13.57 MPa, Assure-dry = 10.74 MPa, Assure-wet = 10.99 MPa). The bond strength for the Assure adhesive was not significantly affected by saliva contamination. The sample of extracted premolars used in this study displayed a greater frequency of buccal surface enamel cracking (46.7%) than that reported in the literature for in vivo premolars (7.8%-10.2%), which was possibly due to the extraction process. The frequency of enamel cracking in a subset of this sample (n = 34) increased from 46.4% at prebonding to 62.4% at postdebonding as a result of the forces of debonding.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11174538     DOI: 10.1067/mod.2001.110519

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  21 in total

1.  The influence of adhesives and the base structure of metal brackets on shear bond strength.

Authors:  Susanne Reimann; Judith Mezey; Nikolaos Daratsianos; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2012-05-12       Impact factor: 1.938

2.  CO2 laser debonding of a ceramic bracket bonded with orthodontic adhesive containing thermal expansion microcapsules.

Authors:  Ayano Saito; Yasuhiro Namura; Keitaro Isokawa; Noriyoshi Shimizu
Journal:  Lasers Med Sci       Date:  2013-11-13       Impact factor: 3.161

3.  A Comparative Study of the Shear and Tensile Bond Strength using three types of Direct Bonding Adhesives on Stainless Steel Brackets - An In Vitro Study.

Authors:  P Sunilkumar; Chandrashekhara Patil; Baswaraj H; Kt Putturaj; Vijaykumar C Sangolgi; K Jayasudha
Journal:  J Int Oral Health       Date:  2013-08-28

4.  Shear bond strength of different adhesives tested in accordance with DIN 13990-1/-2 and using various methods of enamel conditioning.

Authors:  C Richter; P-G Jost-Brinkmann
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

5.  Influence of Adhesives and Methods of Enamel Pretreatment on the Shear Bond Strength of Orthodontic Brackets.

Authors:  Sanja Jurišić; Gordan Jurišić; Hrvoje Jurić
Journal:  Acta Stomatol Croat       Date:  2015-12

6.  Influence of enamel conditioning on the shear bond strength of different adhesives.

Authors:  Lorenz Brauchli; Teodoro Muscillo; Markus Steineck; Andrea Wichelhaus
Journal:  J Orofac Orthop       Date:  2010-11-17       Impact factor: 1.938

7.  Effect of fluoride varnish in combination with simulated oral environment on enamel-bracket shear bond strength.

Authors:  Stefan Lohfeld; Burt Kawamoto; Yong Wang; Mary P Walker
Journal:  Odontology       Date:  2022-06-30       Impact factor: 2.634

8.  Shear bond strength of orthodontic color-change adhesives with different light-curing times.

Authors:  Shahin Bayani; Amirreza Ghassemi; Safa Manafi; Mohadeseh Delavarian
Journal:  Dent Res J (Isfahan)       Date:  2015 May-Jun

9.  A comparative evaluation of the retention of metallic brackets bonded with resin-modified glass ionomer cement under different enamel preparations: A pilot study.

Authors:  Padmaja Sharma; Ashima Valiathan; Ankit Arora; Sachin Agarwal
Journal:  Contemp Clin Dent       Date:  2013-04

10.  Orthodontic molar brackets: the effect of three different base designs on shear bond strength.

Authors:  Athol P Hudson; Sias R Grobler; Angela M P Harris
Journal:  Int J Biomed Sci       Date:  2011-03
View more