OBJECTIVE: To evaluate the role of three-dimensional (3D) ultrasound (US) following needle breast biopsy under two-dimensional (2D) needle guidance.
METHODS: A total of 188 core-needle biopsies and 24 fine-needle aspiration biopsies were 3D US correlated after typical 'freehand' US needle guidance. All cases were examined with a linear 3D US volume scanner (5-13 MHz, Voluson 530D, Medison-Kretztechnik, Zipf, Austria). After core-needle stroke or localization of fine needle, a 3D US data volume set was acquired and a multiplanar analysis performed. This needle position check in all three planes is called '3D targeting'. 66 women with a mean age of 51 years (range, 27-80 years) showed 77 breast lesions (55 solid lesions, 22 cysts) with a mean diameter of 1.5 (range, 0.3-5.0) cm.
RESULTS: In 49 women with 55 solid breast lesions, 16 lesions were malignant and 39 lesions benign. In 53 solid breast lesions 188 core-needle biopsies were performed (mean 3.6 biopsies/lesion). After core-needle biopsy 23 lesions (16 malignant, seven benign) were surgically removed. In 22 cases final histology confirmed results of the core-needle specimen. In one case a core-needle specimen of a 5 mm lesion showed atypical lobular hyperplasia. The definitive histology after surgery was invasive lobular carcinoma. Twenty-two cysts and two benign solid lesions were punctured with a fine needle followed by aspiration biopsy. The overall sensitivity of core-needle results in this study was 94% (specificity 100%, accuracy 0.98, positive predictive value 1, negative predictive value 0.97). In 117 core-needle strokes of benign (21) and malignant (12) lesions 3D targeting prospectively revealed 95 lesion hits, Twelve marginal lesion hits and nine out-of-lesion hits. In one case after the initial large core-needle path a 5-mm lesion was disguised by air bubbles, therefore 3D targeting failed during the second biopsy procedure.
CONCLUSION: 3D US combined with 3D targeting technique is a reliable and objective tool demonstrating exact spatial positioning of core and fine needle during biopsy procedure.

Entities:  

Mesh:

Year:  2000        PMID: 11169313     DOI: 10.1046/j.1469-0705.2000.00182.x

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  8 in total

1.  [3D ultrasound (3D US) in the diagnosis of focal breast lesions].

Authors:  D Kotsianos; S Wirth; T Fischer; K Hiltawsky; H Sittek; M Reiser
Journal:  Radiologe       Date:  2005-03       Impact factor: 0.635

2.  [Transcutaneous ultrasound].

Authors:  M Hünerbein; S S Chopra; P M Schlag
Journal:  Chirurg       Date:  2007-05       Impact factor: 0.955

3.  Comparison between different imaging techniques in the evaluation of malignant breast lesions: can 3D ultrasound be useful?

Authors:  Paola Clauser; Viviana Londero; Giuseppe Como; Rossano Girometti; Massimo Bazzocchi; Chiara Zuiani
Journal:  Radiol Med       Date:  2013-12-03       Impact factor: 3.469

Review 4.  Accuracy of ultrasound-guided, large-core needle breast biopsy.

Authors:  G Schueller; C Schueller-Weidekamm; T H Helbich
Journal:  Eur Radiol       Date:  2008-04-15       Impact factor: 5.315

5.  Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

Authors:  R Schulz-Wendtland; P Dankerl; G Dilbat; M Bani; P A Fasching; K Heusinger; M P Lux; C R Loehberg; S M Jud; C Rauh; C M Bayer; M W Beckmann; D L Wachter; M Uder; M Meier-Meitinger; B Brehm
Journal:  Geburtshilfe Frauenheilkd       Date:  2015-01       Impact factor: 2.915

6.  Three-dimensional ultrasound guidance of autonomous robotic breast biopsy: feasibility study.

Authors:  Kaicheng Liang; Albert J Rogers; Edward D Light; Daniel von Allmen; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2010-01       Impact factor: 2.998

7.  Ultrasound-guided large-core needle biopsies of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification.

Authors:  G Sauer; H Deissler; K Strunz; G Helms; E Remmel; K Koretz; R Terinde; R Kreienberg
Journal:  Br J Cancer       Date:  2005-01-31       Impact factor: 7.640

8.  Interventional procedures in superficial lesions: the value of 2D with additional coronal reformatted 4D ultrasonography guidance.

Authors:  Cheng-Yen Chang; Hsin-Kai Wang; Hong-Jen Chiou; Yi-Hong Chou; Tain-Hsiung Chen; See-Ying Chiou
Journal:  Korean J Radiol       Date:  2006 Jan-Mar       Impact factor: 3.500

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.