In-vitro assessment of a registration protocol for image guided implant dentistry.

W Birkfellner1, P Solar, A Gahleitner, K Huber, F Kainberger, J Kettenbach, P Homolka, M Diemling, G Watzek, H Bergmann.   

Abstract

In this study a computer aided navigation technique for accurate positioning of oral implants was assessed. An optical tracking system with specially designed tools for monitoring the position of surgical instruments relative to the patient was used to register 5 partially or completely edentulous jaw models. Besides the accuracy of the tracking system, the precision of localizing a specific position on 3-dimensional preoperative imagery is governed by the registration algorithm which conveys the coordinate system of the preoperative computed tomography (CT) scan to the actual patient position. Two different point-to-point registration algorithms were compared for their suitability for this application. The accuracy was determined separately for the localization error of the position measurement hardware (fiducial localization error-FLE) and the error as reported by the registration algorithm (fiducial registration error-FRE). The overall error of the navigation procedure was determined as the localization error of additional landmarks (steel spheres, 0.5 mm diameter) after registration (target registration error-TRE). Images of the jaw models were obtained using a high resolution CT scan (1.5 mm slice thickness, 1 mm table feed, incremental scanning, 120 kV, 150 mAs, 512 x 512 matrix, FOV 120 mm). The accuracy of the position measurement probes was 0.69 +/- 0.15 mm (FLE). Using 3 implanted fiducial markers, FRE was 0.71 +/- 0.12 mm on average and 1.00 +/- 0.13 mm maximum. TRE was found to be 1.23 +/- 0.28 mm average and 1.87 +/- 0.47 mm maximum. Increasing the number of fiducial markers to a total of 5 did not significantly improve precision. Furthermore it was found that a registration algorithm based on solving an eigenvalue problem is the superior approach for point-to-point matching in terms of mathematical stability. The experimental results indicate that positioning accuracy of oral implants may benefit from computer aided intraoperative navigation. The accuracy achieved compares well to the resolution of the CT scan used. Further development of point-to-point/point-to-surface registration methods and tracking hardware has the potential to improve the precision of the method even further. Our system has potential to reduce the intraoperative risk of causing damage to critical anatomic structures, to minimize the efforts in prosthetic modelling, and to simplify the task of transferring preoperative planning data precisely to the operating room in general.

Entities:  

Mesh:

Year:  2001        PMID: 11168273     DOI: 10.1034/j.1600-0501.2001.012001069.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  7 in total

1.  Marker-free registration for the accurate integration of CT images and the subject's anatomy during navigation surgery of the maxillary sinus.

Authors:  S-H Kang; M-K Kim; J-H Kim; H-K Park; W Park
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

2.  An on-board surgical tracking and video augmentation system for C-arm image guidance.

Authors:  S Reaungamornrat; Y Otake; A Uneri; S Schafer; D J Mirota; S Nithiananthan; J W Stayman; G Kleinszig; A J Khanna; R H Taylor; J H Siewerdsen
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-04-27       Impact factor: 2.924

3.  An error analysis perspective for patient alignment systems.

Authors:  Michael Figl; Marcus Kaar; Rainer Hoffman; Alfred Kratochwil; Johann Hummel
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-03-06       Impact factor: 2.924

4.  Image-guided surgery and medical robotics in the cranial area.

Authors:  G Widmann
Journal:  Biomed Imaging Interv J       Date:  2007-01-01

5.  Registration of cone beam computed tomography data and intraoral surface scans - A prerequisite for guided implant surgery with CAD/CAM drilling guides.

Authors:  Tabea Flügge; Wiebe Derksen; Jobine Te Poel; Bassam Hassan; Katja Nelson; Daniel Wismeijer
Journal:  Clin Oral Implants Res       Date:  2016-07-20       Impact factor: 5.977

Review 6.  A review of virtual planning software for guided implant surgery - data import and visualization, drill guide design and manufacturing.

Authors:  Florian Kernen; Jaap Kramer; Laura Wanner; Daniel Wismeijer; Katja Nelson; Tabea Flügge
Journal:  BMC Oral Health       Date:  2020-09-10       Impact factor: 2.757

7.  The influence of dental experience on a dental implant navigation system.

Authors:  Ting-Mao Sun; Huey-Er Lee; Ting-Hsun Lan
Journal:  BMC Oral Health       Date:  2019-10-17       Impact factor: 2.757