An in vitro evaluation of the strength of a 1-piece and 2-piece conical abutment joint in implant design.

M R Norton1.   

Abstract

The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the interface between components has been shown to have a profound influence on the stability of screw joints. In this in vitro evaluation, implants utilizing an internal conical joint have demonstrated a parity in resistance to bending moments at the fixture-abutment interface, when comparing a 1-piece abutment to a 2-piece abutment, which is tightened via a separate abutment screw, with mean plastic bending moments of 4176 N mm and 4049 N mm respectively. The very small values for coefficient of variance measured in both systems would confirm that whilst the size of data is small it is nonetheless a reliable indication of the relative strength of these conical joint designs.

Mesh:

Substances:

Year:  2000        PMID: 11168238     DOI: 10.1034/j.1600-0501.2000.011005458.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

1.  Mechanical analysis of conventional and small diameter conical implant abutments.

Authors:  Izabela Cristina Maurício Moris; Adriana Cláudia Lapria Faria; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro; Renata Cristina Silveira Rodrigues
Journal:  J Adv Prosthodont       Date:  2012-08-28       Impact factor: 1.904

2.  Compressive fatigue in titanium dental implants submitted to fluoride ions action.

Authors:  Ana Lúcia Roselino Ribeiro; Jorge Roberto Noriega; Fábio Roberto Dametto; Luís Geraldo Vaz
Journal:  J Appl Oral Sci       Date:  2007-08       Impact factor: 2.698

3.  Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses.

Authors:  Jalil Ghanbarzadeh; Hossin Dashti; Reza Karamad; Marzieh Alikhasi; Mohammadreza Nakhaei
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

4.  Load-Bearing Capacity and Retention of Newly Developed Micro-Locking Implant Prosthetic System: An In Vitro Pilot Study.

Authors:  Jae-Won Choi; Kyung-Hee Choi; Hee-Jin Chae; Sung-Ki Chae; Eun-Bin Bae; Jin-Ju Lee; So-Hyoun Lee; Chang-Mo Jeong; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2018-04-06       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.