Literature DB >> 11168190

Immediate functional loading of Brånemark single tooth implants. An 18 months' clinical pilot follow-up study.

I Ericsson1, H Nilson, T Lindh, K Nilner, K Randow.   

Abstract

A clinical and radiographical study was performed to evaluate the treatment outcome of single tooth replacements with artificial crowns retained to implants installed according to a 1-stage surgical procedure and immediate loading (Experimental Group = EG) in comparison to the original 2-stage concept (Control Group = CG). The EG comprised 14 patients (= 14 implants) and the CG comprised 8 patients (= 8 implants), all with single tooth losses anterior to the molars. Beyond the non-smoking criterion the following criteria were adopted: i) the amount of bone had to allow for installation of a fixture with a minimum length of 13 mm and Ø = 3.75 mm, ii) the jaw relationship had to allow for bilateral occlusal stability, iii) the patients should be judged to be non-bruxers, and iv) the patients had to be available for the follow-up and maintenance programme. In the EG a temporary crown was connected to the implant within 24 h following fixture installation. Six months later this crown was replaced with a permanent one. In the CG the surgical and prosthetic treatment followed the standard protocol. Out of the 14 fixtures in the EG 2 were lost up to 5 months in function and were subsequently removed. All remaining 12 implants were stable at every subsequent follow-up examination. No fixture losses were recorded in the CG and all implants in this group were stable at the follow-ups. At the 6-month observation interval all the participating 20 patients were radiographically examined, an examination that was repeated at the 18-month follow-up. The analysis of the radiographs from the EG as well as from the CG disclosed that during the 12-month observation period the mean change of bone support was about 0.1 mm. Further studies, designed as controlled multicenter ones, have to be performed before the results of this pilot study can be recommended for more general use.

Entities:  

Mesh:

Year:  2000        PMID: 11168190     DOI: 10.1034/j.1600-0501.2000.011001026.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  10 in total

1.  [Microbiological study on the prognosis of immediate implant and periodontal disease].

Authors:  A Rabel; S G Köhler
Journal:  Mund Kiefer Gesichtschir       Date:  2006-01

2.  Immediate loading: a new implant technique with immediate loading and aesthetics: Nobel Active™.

Authors:  D Moretto; M Gargari; E Nordsjö; F Gloria; L Ottria
Journal:  Oral Implantol (Rome)       Date:  2009-02-01

3.  3D finite element non linear analysis on the stress state at bone-implant interface in dental osteointegrated implants.

Authors:  G Sannino; G Marra; L Feo; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2011-01-13

4.  Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study.

Authors:  Seok-Gyu Kim; Pil-Young Yun; Hyun-Sik Park; June-Sung Shim; Jung-Won Hwang; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

5.  Marginal bone level change during sequential loading periods of partial edentulous rehabilitation using immediately loaded self-tapping implants: a 6.5-year retrospective study.

Authors:  Jing Wang; Zhengchuan Zhang; Feilong Deng
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

6.  Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading.

Authors:  Rico Rutkowski; Ralf Smeets; Leon Neuhöffer; Carolin Stolzer; Kilian Strick; Martin Gosau; Susanne Sehner; Karl Ulrich Volz; Anders Henningsen
Journal:  BMC Oral Health       Date:  2022-05-23       Impact factor: 3.747

7.  A Simplified Prosthetic Implant Loading Protocol: 1-Year Clinical Follow-Up Study.

Authors:  Lorenzo Andreatta; Malin Bjursten Brailsford; Jakob Zwaan
Journal:  Int J Dent       Date:  2020-08-03

8.  Immediately Loaded Single Unit Dental Implants: A Clinical Study.

Authors:  Shweta Rai; Anurag Rai; Tanoj Kumar; Minti Kumari; Muthyalu Kumar Somanna; Subhash Bandgar
Journal:  J Pharm Bioallied Sci       Date:  2020-08-28

9.  A 5-year comparison of marginal bone level following immediate loading of single-tooth implants placed in healed alveolar ridges and extraction sockets in the maxilla.

Authors:  Antoine N Berberi; Joseph M Sabbagh; Moustafa N Aboushelib; Ziad F Noujeim; Ziad A Salameh
Journal:  Front Physiol       Date:  2014-01-31       Impact factor: 4.566

10.  Immediate Loading of Implant-Supported Single Crowns after Conventional and Ultrasonic Implant Site Preparation: A Multicenter Randomized Controlled Clinical Trial.

Authors:  Claudio Stacchi; Teresa Lombardi; Domenico Baldi; Calogero Bugea; Antonio Rapani; Giuseppe Perinetti; Angelo Itri; David Carpita; Guido Audenino; Giuseppe Bianco; Simone Verardi; Stefano Carossa; Gianmario Schierano
Journal:  Biomed Res Int       Date:  2018-08-14       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.