Literature DB >> 11161176

Improved MR flow mapping in coronary artery bypass grafts during adenosine-induced stress.

S E Langerak1, P Kunz, H W Vliegen, H J Lamb, J W Jukema, E E van Der Wall, A de Roos.   

Abstract

PURPOSE: To validate a recently developed fast high-temporal-resolution magnetic resonance (MR) flow sequence and use it to assess coronary artery bypass graft function during pharmacologic stress.
MATERIALS AND METHODS: Aortic and internal mammary artery flow was measured in 11 healthy volunteers by using conventional cine gradient-echo imaging as a reference standard method and turbo-field echo-planar imaging (TFEPI). By using TFEPI, breath-hold flow mapping with a spatial and temporal resolution of 0.8 mm(2) and 23 msec, respectively, can be performed. This sequence was applied in 20 angiographically normal grafts, and total blood flow at rest and during adenosine infusion (140 microgram/kg/min) was measured.
RESULTS: Good agreement in aortic and internal mammary artery flow values between conventional fast-field echo and TFEPI techniques was found. The mean bypass graft total flow (+/- SD), as assessed with TFEPI, increased from 30.8 mL/min +/- 13.5 to 76.7 mL/min +/- 36.5 (P <.05) to yield a flow reserve of 2.7. Furthermore, this sequence revealed a difference in total flow between single and sequential grafts at rest (25.4 mL/min vs 40.9 mL/min; P <.05) and during stress (65.2 mL/min vs 98.3 mL/min; P <.05).
CONCLUSION: Breath-hold TFEPI provides fast accurate flow measurements with high temporal resolution and allows motion-compensated flow quantification in multiple coronary artery bypass grafts during one 6-minute adenosine infusion.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11161176     DOI: 10.1148/radiology.218.2.r01fe22540

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

Review 1.  Magnetic resonance imaging in detection and functional assessment of coronary artery disease.

Authors:  Wojciech Mazur; Steffen Brucks; Stephen N Darty; Pairoj Rerkpattanapipat
Journal:  Curr Atheroscler Rep       Date:  2002-03       Impact factor: 5.113

2.  Non-invasive coronary imaging: computed tomography or magnetic resonance imaging?

Authors:  C R Peebles
Journal:  Heart       Date:  2003-06       Impact factor: 5.994

Review 3.  Cardiovascular nuclear magnetic resonance: basic and clinical applications.

Authors:  John R Forder; Gerald M Pohost
Journal:  J Clin Invest       Date:  2003-06       Impact factor: 14.808

4.  Magnetic resonance imaging for the non-invasive detection of stenosis in coronary artery bypass grafts: clinical reality?

Authors:  E E van der Wall; S E Langerak
Journal:  Int J Cardiovasc Imaging       Date:  2002-12       Impact factor: 2.357

5.  MRI in the detection of stenosis in coronary artery bypass grafts: are invasive techniques still needed?

Authors:  S E Langerak; E E van der Wall
Journal:  Neth Heart J       Date:  2003-01       Impact factor: 2.380

6.  Experimental measurement of dynamic fluid shear stress on the ventricular surface of the aortic valve leaflet.

Authors:  Choon Hwai Yap; Neelakantan Saikrishnan; Ajit P Yoganathan
Journal:  Biomech Model Mechanobiol       Date:  2011-04-05

7.  Comparison of intraoperative transit-time flow measurement with early postoperative magnetic resonance flow mapping in off-pump coronary artery surgery.

Authors:  Ilhan Sanisoglu; Mustafa Guden; Cem Balci; Ertan Sagbas; Cihan Duran; Belhhan Akpinar
Journal:  Tex Heart Inst J       Date:  2003

8.  Influence of acquired obesity on coronary vessel wall late gadolinium enhancement in discordant monozygote twins.

Authors:  Marcus R Makowski; Christian H P Jansen; Ullrich Ebersberger; Tobias Schaeffter; Reza Razavi; Massimo Mangino; Tim D Spector; Rene M Botnar; Gerald F Greil
Journal:  Eur Radiol       Date:  2016-10-14       Impact factor: 5.315

Review 9.  Cardiovascular magnetic resonance phase contrast imaging.

Authors:  Krishna S Nayak; Jon-Fredrik Nielsen; Matt A Bernstein; Michael Markl; Peter D Gatehouse; Rene M Botnar; David Saloner; Christine Lorenz; Han Wen; Bob S Hu; Frederick H Epstein; John N Oshinski; Subha V Raman
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-09       Impact factor: 5.364

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.