Literature DB >> 11157372

Increasing dialysate flow rate increases dialyzer urea mass transfer-area coefficients during clinical use.

R Ouseph1, R A Ward.   

Abstract

Dialyzer clearance depends on blood and dialysate flow rates and the product of the membrane surface area and mass transfer coefficient for the solute of interest, K(o)A. K(o)A is usually assumed to be constant for a given dialyzer and solute. Results of two recent studies challenge this assumption. Therefore, we examined the hypothesis that K(o)A depends on blood and dialysate flow rates during clinical dialysis. Urea clearances were measured for two different dialyzers at all four combinations of two blood flow rates (300 and 400 mL/min) and two dialysate flow rates (500 and 800 mL/min). Urea K(o)A was calculated by using standard equations for mass transfer in dialyzers operated with countercurrent flows. The impact of blood and dialysate flow rates on K(o)A was assessed by analysis of variance. Increasing dialysate flow rate from 500 to 800 mL/min significantly increased K(o)A (P = 0.018). Increasing blood flow rate from 300 to 400 mL/min did not significantly increase K(o)A (P = 0.083). Also, K(o)A decreased significantly with increasing hematocrit (P = 0.022). The results of this study extend previous in vitro findings by showing that increasing the dialysate flow rate increases urea K(o)A during clinical dialysis. However, the increase in K(o)A observed during clinical dialysis (5.7%) is less than that previously reported in vitro (14.7%), possibly because of the impact of blood cells and proteins on blood-side mass transfer resistance.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11157372     DOI: 10.1053/ajkd.2001.21296

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  14 in total

1.  Renal Association Clinical Practice Guideline on Haemodialysis.

Authors:  Damien Ashby; Natalie Borman; James Burton; Richard Corbett; Andrew Davenport; Ken Farrington; Katey Flowers; James Fotheringham; R N Andrea Fox; Gail Franklin; Claire Gardiner; R N Martin Gerrish; Sharlene Greenwood; Daljit Hothi; Abdul Khares; Pelagia Koufaki; Jeremy Levy; Elizabeth Lindley; Jamie Macdonald; Bruno Mafrici; Andrew Mooney; James Tattersall; Kay Tyerman; Enric Villar; Martin Wilkie
Journal:  BMC Nephrol       Date:  2019-10-17       Impact factor: 2.388

2.  Dialysate flow rate and delivered Kt/Vurea for dialyzers with enhanced dialysate flow distribution.

Authors:  Richard A Ward; John W Idoux; Hiba Hamdan; Rosemary Ouseph; Thomas A Depner; Thomas A Golper
Journal:  Clin J Am Soc Nephrol       Date:  2011-07-28       Impact factor: 8.237

3.  Replication of fouling in vitro in hollow fiber dialyzers by albumin immobilization.

Authors:  Takayoshi Kiguchi; Narumi Tomisawa; Akihiro C Yamashita
Journal:  J Artif Organs       Date:  2022-02-11       Impact factor: 1.731

4.  Pharmacometric characterization of dabigatran hemodialysis.

Authors:  Karl-Heinz Liesenfeld; Alexander Staab; Sebastian Härtter; Stephan Formella; Andreas Clemens; Thorsten Lehr
Journal:  Clin Pharmacokinet       Date:  2013-06       Impact factor: 6.447

5.  Second Generation Nanoporous Silicon Nitride Membranes for High Toxin Clearance and Small Format Hemodialysis.

Authors:  Kayli Hill; Samuel N Walker; Alec Salminen; Hung L Chung; Xunzhi Li; Bahie Ezzat; Joshua J Miller; Jon-Paul S DesOrmeaux; Jingkai Zhang; Andrew Hayden; Tucker Burgin; Lindsay Piraino; Marina N May; Thomas R Gaborski; James A Roussie; Jeremy Taylor; Louis DiVincenti; Alexander A Shestopalov; James L McGrath; Dean G Johnson
Journal:  Adv Healthc Mater       Date:  2020-01-15       Impact factor: 9.933

6.  Effect of increasing dialysate flow rate on diffusive mass transfer of urea, phosphate and beta2-microglobulin during clinical haemodialysis.

Authors:  Jai P Bhimani; Rosemary Ouseph; Richard A Ward
Journal:  Nephrol Dial Transplant       Date:  2010-06-13       Impact factor: 5.992

Review 7.  Mass Transport in High-Flux Hemodialysis: Application of Engineering Principles to Clinical Prescription.

Authors:  Farzad Mohajerani; William R Clark; Claudio Ronco; Vivek Narsimhan
Journal:  Clin J Am Soc Nephrol       Date:  2022-03-11       Impact factor: 10.614

8.  Impact of stepwise sodium and ultra filtration profiles and dialysis solution flow rate profile on dialysis adequacy.

Authors:  Nahid Shahgholian; Azam Salehi; Mojgan Mortazavi
Journal:  Iran J Nurs Midwifery Res       Date:  2014-09

9.  Is it useful to increase dialysate flow rate to improve the delivered Kt?

Authors:  Marta Albalate; Rafael Pérez-García; Patricia de Sequera; Elena Corchete; Roberto Alcazar; Mayra Ortega; Marta Puerta
Journal:  BMC Nephrol       Date:  2015-02-14       Impact factor: 2.388

10.  Protein-Bound Uremic Toxin Profiling as a Tool to Optimize Hemodialysis.

Authors:  Sunny Eloot; Daniel Schneditz; Tom Cornelis; Wim Van Biesen; Griet Glorieux; Annemie Dhondt; Jeroen Kooman; Raymond Vanholder
Journal:  PLoS One       Date:  2016-01-22       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.