Negative pressures during swing phase in below-knee prostheses with rubber sleeve suspension.

N Chino, J R Pearson, J L Cockrell, H A Mikishko, G H Koepke.   

Abstract

Negative pressures in the small space between the distal stump and the below-knee prosthetic socket were measured during swing phase for a series of nine subjects. A molded rubber sleeve connecting the prosthesis and the thigh was found to enhance this effect so that suction suspension occurred during the entire swing phase. Deterioration of the suction occurred when the sleeve was intentionally pierced, and when other suspensions such as a suprapatellar cuff or thigh band were tested. The findings indicate that the total-contact socket, gel liner and elastic sleeve combine to create suction in the below-knee socket which improves overall comfort and function for the patient in using the prosthesis.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1115589

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  5 in total

Review 1.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

2.  Effectiveness of elevated vacuum and suction prosthetic suspension systems in managing daily residual limb fluid volume change in people with transtibial amputation.

Authors:  Robert T Youngblood; Jacob T Brzostowski; Brian J Hafner; Joseph M Czerniecki; Katheryn J Allyn; Richard L Foster; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2020-03-18       Impact factor: 1.895

3.  Development of an air pneumatic suspension system for transtibial prostheses.

Authors:  Gholamhossein Pirouzi; Noor Azuan Abu Osman; Azim Ataollahi Oshkour; Sadeeq Ali; Hossein Gholizadeh; Wan A B Wan Abas
Journal:  Sensors (Basel)       Date:  2014-09-09       Impact factor: 3.576

Review 4.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

5.  Real time monitoring of transtibial elevated vacuum prostheses: A case series on socket air pressure.

Authors:  Katherine R Schoepp; Jonathon S Schofield; David Home; Michael R Dawson; Edmond Lou; McNiel Keri; Paul D Marasco; Jacqueline S Hebert
Journal:  PLoS One       Date:  2018-10-22       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.