Benefits in projected pacemaker longevity and in pacing related costs conferred by automatic threshold tracking.

G Boriani1, M Biffi, A Branzi, A Mininno, R Sigliano.   

Abstract

The aim of this study was to calculate the battery current drain of different VVI-VVIR pulse generators, with and without automatic adjustment of stimulation output, from the same manufacturer, and obtain projections on pacemaker longevity and pacing related costs. Twenty-five patients who had received a VVIR pacemaker (Microny SR+ 2425T) with Autocapture function, an algorithm able to provide automatic adaptation of device output coupled with continuously monitored capture threshold, were analyzed. Calculations of current drain and projections of device longevity were based on diagnostic data retrieved from device memory and on comparisons of multiple programmed settings of the same device (Microny SR+ 2425T with Autocapture, Low Output [output = 2 x Autocapture threshold, but not less than 2.4 V] versus Standard Output [5 V]). In addition, devices with Autocapture but with different battery capacities (0.35 Ah and 0.79 Ah, Microny and Regency, respectively) were compared to a standard device (battery capacity = 0.78 Ah) at 2.5-V and 5-V output settings. According to a series of assumptions, Autocapture increased device longevity by 53% (Microny) and by 245% (Regency) over a 15-year follow-up with a consequent reduction in pacing related costs of 25% (Microny) and of 57% (Regency) compared to the standard settings of a VVIR device from the same manufacturer. In conclusion, pacing with constant adaptation of generator output coupled with continuous monitoring of stimulation threshold has the potential to increase generator longevity and to reduce pacing related costs as compared to a standard device from the same manufacturer.

Entities:  

Mesh:

Year:  2000        PMID: 11139923     DOI: 10.1111/j.1540-8159.2000.tb07018.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Clinical observation of atrial threshold monitoring algorithm: a single center experience.

Authors:  Jianqing She; Jing Zhou; Zhan Hu; Yulong Xia
Journal:  Int J Clin Exp Med       Date:  2015-04-15

2.  Influence Of Inter Electrode Atrial Lead Distance On Acapconfirm™ Viability.

Authors:  Irigoyen J A Lapuerta; Andre I Valverde; Escalera P Vigil; Gonzalez M Vasserot
Journal:  J Atr Fibrillation       Date:  2016-08-31

3.  The influence of mental and physical stress on the autocapture function in children.

Authors:  Tevfik Karagoz; Alpay Celiker
Journal:  J Interv Card Electrophysiol       Date:  2003-08       Impact factor: 1.900

4.  [Efficiency potential in the pacemaker/implantable cardioverter defibrillator outpatient clinic].

Authors:  A Bauer; J Bauer; M Bauer; K Kelemen; F Voss; J Senges-Becker; S Weretka; H A Katus; R Becker
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2006-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.