Literature DB >> 11137410

Evaluation of the cardiovascular responses to fiberoptic orotracheal intubation with television monitoring: comparison with conventional direct laryngoscopy.

Y U Adachi1, I Takamatsu, K Watanabe, Y Uchihashi, H Higuchi, T Satoh.   

Abstract

STUDY
OBJECTIVE: To evaluate and compare cardiovascular responses to a new method of orotracheal intubation incorporating TV monitoring, with conventional orotracheal intubation via rigid blade laryngoscopy.
DESIGN: Prospective single-blind study.
SETTING: Operating room of a medical college hospital. PATIENTS: 90 ASA physical status I and II surgical patients requiring general anesthesia and orotracheal intubation.
INTERVENTIONS: Patients were randomly allocated to two groups, one for the new intubation method and the other for conventional intubation using a rigid laryngoscope. In the new method, an anesthesiologist inserted an endotracheal tube alone into the trachea via TV monitoring through the bronchoscope, which was inserted by an assistant through the mouth to the middle larynx. The patient's trachea was intubated without extreme stretching of laryngeal tissues or deep insertion of the tip of the bronchoscope. In the conventional method, orotracheal intubation was performed with rigid direct laryngoscopy. MEASUREMENTS: Noninvasive blood pressure (BP) and heart rate (HR) were measured before arrival at the operating room, and before and after orotracheal intubation. MAIN
RESULTS: Although this method was expected to be a minimally invasive fiberoptic intubation technique, the patients showed significant increases in BP and HR. No significant differences between the two groups were observed in cardiovascular responses immediately after intubation: the systolic BP, 169.5 +/- 28.3 versus 167.0 +/- 23.1 mmHg, and HR, 100.2 +/- 18.2 versus 98.8 +/- 16.6 bpm.
CONCLUSIONS: Insertion of an endotracheal tube may itself be the most invasive stimulus during intubation procedures.

Entities:  

Mesh:

Year:  2000        PMID: 11137410     DOI: 10.1016/s0952-8180(00)00196-3

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  7 in total

1.  Comparison of Orotracheal versus Nasotracheal Fiberoptic Intubation Using Hemodynamic Parameters in Patients with Anticipated Difficult Airway.

Authors:  Jitendra Singh Chahar; Pravin Kumar Das; Rakesh K Dubey; Deepak Malviya; Mamta Harjai; Shivani Rastogi
Journal:  Anesth Essays Res       Date:  2020-06-22

2.  Haemodynamic response at double lumen bronchial tube placement - Airtraq vs. MacIntosh laryngoscope, a randomised controlled trial.

Authors:  Thomas Hamp; Thomas Stumpner; Georg Grubhofer; Kurt Ruetzler; Rainer Thell; Helmut Hager
Journal:  Heart Lung Vessel       Date:  2015

3.  Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine.

Authors:  Nitesh Gill; Shobha Purohit; Poonam Kalra; Tarun Lall; Avneesh Khare
Journal:  Anesth Essays Res       Date:  2015 Sep-Dec

4.  Comparison of hemodynamic responses to endotracheal intubation with the GlideScope video laryngoscope and Macintosh laryngoscope in patients undergoing cardiovascular surgery.

Authors:  Gökhan İnangil; Kadir Hakan Cansız; Fuat Gürbüz; Ömer Bakal; Fatma Merih Gökben; Hüseyin Şen
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-07-03       Impact factor: 0.332

5.  Comparison of haemodynamic responses to intubation: Flexible fibreoptic bronchoscope versus bonfils rigid intubation endoscope.

Authors:  Kapil Gupta; Kiran Kumar Girdhar; Raktima Anand; Sumanth Mallikarjuna Majgi; Surinder Pal Gupta; Payal Bansal Gupta
Journal:  Indian J Anaesth       Date:  2012-07

6.  Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial.

Authors:  Ali Reza Pournajafian; Mohammad Reza Ghodraty; Seyed Hamid Reza Faiz; Poupak Rahimzadeh; Hamidreza Goodarzynejad; Enseyeh Dogmehchi
Journal:  Iran Red Crescent Med J       Date:  2014-04-05       Impact factor: 0.611

7.  A study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope.

Authors:  Mansoor Aqil
Journal:  Pak J Med Sci       Date:  2014-09       Impact factor: 1.088

  7 in total