Literature DB >> 11131203

Diagnostic reference levels in interventional radiology.

N W Marshall1, C L Chapple, C J Kotre.   

Abstract

Following the release of European Directive EU 97/43, radiodiagnostic facilities within the European Union are required to implement a system of patient dose reviews based on comparisons with European, national and local diagnostic reference levels (DRLs). Establishing these levels for typical interventional radiology examinations presents a problem as definition of 'typical' examinations can be difficult, patient numbers are limited and these procedures are often performed at a few specialist centres. This paper uses dose-area product (DAP) gathered over a period of 3 years from 40 fluoroscopy rooms to investigate potential difficulties when it comes to forming diagnostic reference levels for interventional radiology. Comparison of DAP distributions with standard complex (fluoroscopy based) examinations such as barium enema reveals considerably more variation for interventional procedures. Two methods of forming a DRL are compared: pooled patient DAP distributions versus a distribution of DAP per room. The bootstrap resampling method is then applied to DAP distributions to form a confidence interval for the chosen DRL statistic. Potential error on a DRL formed at a local level from a limited number of patient dose readings and x-ray rooms is significant. The results are reviewed in the wider context of DRLs in general radiology. For complex examinations, it is suggested that the function of the DRL is best served by setting DRLs based on pooled size-corrected patient DAP distributions rather than distributions of average DAP per room.

Entities:  

Mesh:

Year:  2000        PMID: 11131203     DOI: 10.1088/0031-9155/45/12/323

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Radiation dose in vertebroplasty.

Authors:  A Mehdizade; K O Lovblad; K E Wilhelm; T Somon; S G Wetzel; A D Kelekis; H Yilmaz; G Abdo; J B Martin; J M Viera; D A Rüfenacht
Journal:  Neuroradiology       Date:  2004-02-14       Impact factor: 2.804

2.  How to set up and apply reference levels in fluoroscopy at a national level.

Authors:  A Aroua; H Rickli; J-C Stauffer; P Schnyder; P R Trueb; J-F Valley; P Vock; F R Verdun
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

3.  Radiation dose and risk from fluoroscopically guided percutaneous transluminal angioplasty and stenting in the abdominal region.

Authors:  John Stratakis; John Damilakis; Dimitrios Tsetis; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2007-03-27       Impact factor: 5.315

4.  Patient radiation doses and reference levels in pediatric interventional radiology.

Authors:  Bouchra Habib Geryes; Adeline Bak; Julie Lachaux; Augustin Ozanne; Nathalie Boddaert; Francis Brunelle; Olivier Naggara; Guillaume Saliou
Journal:  Eur Radiol       Date:  2017-02-16       Impact factor: 5.315

5.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Authors:  Donald L Miller; Deukwoo Kwon; Grant H Bonavia
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

6.  Reference levels and patient doses in interventional cardiology procedures in Greece.

Authors:  George Simantirakis; Christina Koukorava; Maria Kalathaki; Christos Pafilis; Ioannis Kaisas; Sotirios Economides; Costas J Hourdakis; Vassiliki Kamenopoulou; Evaggelos Georgiou
Journal:  Eur Radiol       Date:  2013-04-06       Impact factor: 5.315

7.  Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.

Authors:  E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford
Journal:  Eur Radiol       Date:  2017-05-18       Impact factor: 5.315

8.  Proposed achievable levels of dose and impact of dose-reduction systems for thrombectomy in acute ischemic stroke: an international, multicentric, retrospective study in 1096 patients.

Authors:  Adrien Guenego; Pascal J Mosimann; Vitor Mendes Pereira; Patrick Nicholson; Kevin Zuber; Jean Albert Lotterie; Tomas Dobrocky; David G Marcellus; Jean Marc Olivot; Michel Piotin; Jan Gralla; Robert Fahed; Max Wintermark; Jeremy J Heit; Christophe Cognard
Journal:  Eur Radiol       Date:  2019-03-22       Impact factor: 5.315

9.  Patient radiation dose in diagnostic and interventional procedures for intracranial aneurysms: experience at a single center.

Authors:  Chang Woo Chun; Bum-Soo Kim; Cheol Hyoun Lee; Yon Kwon Ihn; Yong-Sam Shin
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

Review 10.  Patient radiation dose in percutaneous biliary interventions: recommendations for DRLs on the basis of a multicentre study.

Authors:  Daniel Schmitz; Thomas Vogl; Nour-Eldin Abdelrehim Nour-Eldin; Boris Radeleff; Jens-Christian Kröger; Andreas H Mahnken; Harald Ittrich; Hans-Björn Gehl; Bernd Plessow; Joachim Böttcher; Josef Tacke; Markus Wispler; Ulrich Rosien; Wolfgang Schorr; Markus Joerdens; Nicolas Glaser; Erik-Sebastian Fuchs; Andrea Tal; Bettina Friesenhahn-Ochs; Thomas Leimbach; Lars Höpner; Marko Weber; Stefan Gölder; Michael Böhmig; Svetlana Hetjens; Jochen Rudi; Alexander Schegerer
Journal:  Eur Radiol       Date:  2019-04-23       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.