Literature DB >> 11130387

Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis.

R Köster1, D Vieluf, M Kiehn, M Sommerauer, J Kähler, S Baldus, T Meinertz, C W Hamm.   

Abstract

BACKGROUND: Coronary in-stent restenosis might be triggered by contact allergy to nickel, chromate, or molybdenum ions released from stainless-steel stents. We investigated the association between allergic reactions to stent components and the occurrence of in-stent restenosis.
METHODS: Patients with coronary stainless-steel stents who underwent angiography for suspected restenosis were consecutively included in this study. Quantitative coronary angiography for analysis of percentage diameter stenosis was done on 131 patients (mean age 62 years [SD 9]) with 171 stents 6.1 months (2.7) after stent implantation. All patients underwent epicutaneous patch tests (Finn chamber method) for nickel, chromate, molybdenum, manganese, and small 316L stainless-steel plates. Patch tests were assessed by independent dermatologists after 48 h, 72 h, and when necessary 96 h of contact with the potential allergen.
FINDINGS: In-stent restenosis (> or =550% diameter stenosis) occurred in 89 patients. All ten patients with positive patch-test results had restenoses (p=0.03). Four male patients had positive reactions to molybdenum, and seven patients (four male, three female) had reactions to nickel. No patient with an allergic reaction to the standard test substances had a positive reaction to the stainless-steel plates. All patients with positive results had recurrent angina pectoris and needed target-vessel revascularisation.
INTERPRETATION: Patients with allergic patch-test reactions to nickel and molybdenum had a higher frequency of in-stent restenoses than patients without hypersensitivity. Allergic reactions to nickel and molybdenum released from stents may be one of the triggering mechanisms for in-stent restenosis.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11130387     DOI: 10.1016/S0140-6736(00)03262-1

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  57 in total

1.  Long-term angiographic outcomes of post-sirolimus-eluting stent restenosis in Japanese patients.

Authors:  Nobuyuki Miyai; Noriyuki Kinoshita; Keisuke Oota; Takeshi Yamada; Reo Nakamura; Hidekazu Irie; Tetsuo Hashimoto; Shyunichi Tamaki; Hiroaki Matsubara
Journal:  Heart Vessels       Date:  2010-10-27       Impact factor: 2.037

Review 2.  Atrial septum defect closure device in a beating heart, from the perspective of a researcher in artificial organs.

Authors:  Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-06-23       Impact factor: 1.731

3.  First in-human randomized comparison of an anodized niobium stent versus a standard stainless steel stent--an intravascular ultrasound and angiographic two-center study: the VELA study.

Authors:  F Beier; M Gyöngyösi; T Raeder; E von Eckardstein-Thumb; W Sperker; P Albrecht; C Spes; D Glogar; H Mudra
Journal:  Clin Res Cardiol       Date:  2006-07-03       Impact factor: 5.460

Review 4.  The cell cycle: a critical therapeutic target to prevent vascular proliferative disease.

Authors:  Thierry Charron; Nafiseh Nili; Bradley H Strauss
Journal:  Can J Cardiol       Date:  2006-02       Impact factor: 5.223

Review 5.  Systemic contact dermatitis and allergy to biomedical devices.

Authors:  Marcella Aquino; Tania Mucci
Journal:  Curr Allergy Asthma Rep       Date:  2013-10       Impact factor: 4.806

Review 6.  Delivery of large biopharmaceuticals from cardiovascular stents: a review.

Authors:  Hironobu Takahashi; Didier Letourneur; David W Grainger
Journal:  Biomacromolecules       Date:  2007-10-12       Impact factor: 6.988

7.  Pathological analysis of a case with peri-stent contrast staining after BMS implantation.

Authors:  Masao Imai; Atsuo Fukuda; Nobuhide Miyamoto; Hidenori Sako; Takeshi Kimura; Katsumi Inoue
Journal:  J Cardiol Cases       Date:  2016-09-09

8.  Corrosion resistance improvement for 316L stainless steel coronary artery stents by trimethylsilane plasma nanocoatings.

Authors:  John Eric Jones; Meng Chen; Qingsong Yu
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-02-06       Impact factor: 3.368

9.  TiNi shape memory alloy coated with tungsten: a novel approach for biomedical applications.

Authors:  Huafang Li; Yufeng Zheng; Y T Pei; J Th M De Hosson
Journal:  J Mater Sci Mater Med       Date:  2014-01-31       Impact factor: 3.896

10.  Stainless steel ions stimulate increased thrombospondin-1-dependent TGF-beta activation by vascular smooth muscle cells: implications for in-stent restenosis.

Authors:  Manuel A Pallero; Melissa Talbert Roden; Yiu-Fai Chen; Peter G Anderson; Jack Lemons; Brigitta C Brott; Joanne E Murphy-Ullrich
Journal:  J Vasc Res       Date:  2009-12-16       Impact factor: 1.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.