Literature DB >> 11130130

A fibreoptic scoring system to assess the position of laryngeal mask airway devices. Interobserver variability and a comparison between the standard, flexible and intubating laryngeal mask airways.

C Keller1, J Brimacombe, F Pühringer.   

Abstract

We determined the interobserver reliability of a fibreoptic scoring system for assessing the position of the laryngeal mask airway (LMA), the flexible laryngeal mask airway (FLMA) and the intubating laryngeal mask airway (ILM). We also compare fibreoptic position between the devices. Thirty anaesthetised adult patients were studied in random order in a triple crossover manner. Two observers blinded to each others findings scored the fibreoptic position as follows: 4, only vocal cords visible; 3, vocal cords plus posterior epiglottis visible; 2, vocal cords plus anterior epiglottis visible; 1, vocal cords not seen. Interobserver reliability was examined using intraclass correlation coefficient (ICC). Interobserver reliability was graded as excellent for the LMA (ICC = 0.89), FLMA (ICC = 0.87) and ILM (ICC = 0.79). Fibreoptic scores were higher for the LMA and FLMA compared with the ILM (both p < 0.001). We conclude that interobserver reliability for the fibreoptic scoring system is excellent for the LMA, FLMA and ILM. Fibreoptic position is better for the LMA and FLMA compared with the ILM. Fibreoptic scoring has potential utility for research and clinical practice with laryngeal mask devices.

Entities:  

Mesh:

Year:  2000        PMID: 11130130     DOI: 10.1055/s-2000-8164

Source DB:  PubMed          Journal:  Anasthesiol Intensivmed Notfallmed Schmerzther        ISSN: 0939-2661            Impact factor:   0.698


  20 in total

1.  Evaluation of the Dams TuLip-i™: a new airway device for flexible bronchoscopic intubation.

Authors:  Takanobu Uesugi
Journal:  Can J Anaesth       Date:  2019-05-06       Impact factor: 5.063

2.  PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy.

Authors:  Bimla Sharma; Raminder Sehgal; Chand Sahai; Jayashree Sood
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2010-10

3.  Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial.

Authors:  Sandeep Kumar Mishra; Mohammad Nawaz; M V S Satyapraksh; Satyen Parida; Prasanna Udupi Bidkar; Balachander Hemavathy; Pankaj Kundra
Journal:  Anesthesiol Res Pract       Date:  2015-01-11

4.  The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices.

Authors:  Zanahriah Yahaya; Wendy H Teoh; Nora A Dintan; Ravi Agrawal
Journal:  Anesthesiol Res Pract       Date:  2016-10-25

5.  Supraglottic airway devices as a strategy for unassisted tracheal intubation: A network meta-analysis.

Authors:  EunJin Ahn; GeunJoo Choi; Hyun Kang; ChongWha Baek; YongHun Jung; YoungCheol Woo; SiRa Bang
Journal:  PLoS One       Date:  2018-11-05       Impact factor: 3.240

6.  Comparison of Different Cuff Pressure Use with the Supreme Laryngeal Mask Airway on Haemodynamic Response, Seal Pressure and Postoperative Adverse Events: A Prospective Randomized Study.

Authors:  Achmet Ali; Demet Altun; Nukhet Sivrikoz; Mesut Yornuk; Namigar Turgut; İbrahim Özkan Akıncı
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-11-27

7.  Comparison of clinical performance of the I-gel with LMA proseal.

Authors:  Gaurav Chauhan; Pavan Nayar; Anita Seth; Kapil Gupta; Mamta Panwar; Nidhi Agrawal
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-01

8.  ProSeal™ laryngeal mask airway cuff pressure changes with and without use of nitrous oxide during laparoscopic surgery.

Authors:  Bimla Sharma; Rajat Gupta; Raminder Sehgal; Archna Koul; Jayashree Sood
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-01

9.  Effect of Paralysis at the Time of ProSeal Laryngeal Mask Airway Insertion on Pharyngolaryngeal Morbidities. A Randomized Trial.

Authors:  Hyo-Seok Na; Young-Tae Jeon; Hyun-Jung Shin; Ah-Young Oh; Hee-Pyoung Park; Jung-Won Hwang
Journal:  PLoS One       Date:  2015-08-07       Impact factor: 3.240

10.  Comparison of i-gel® and LMA Supreme® during laparoscopic cholecystectomy.

Authors:  Sang Yoong Park; Jong Cheol Rim; Hyuk Kim; Ji Hyeon Lee; Chan Jong Chung
Journal:  Korean J Anesthesiol       Date:  2015-09-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.