Determination of the voltage applied to x-ray tubes from the bremsstrahlung spectrum obtained with a silicon PIN photodiode.

M C Silva1, S B Herdade, P Lammoglia, P R Costa, R A Terini.   

Abstract

This work describes a methodology for the obtainment of the electron accelerating potential (kVp) applied to an x-ray tube, through the determination of the end point of the energy spectrum of the radiation emitted by the tube. The measurements have been performed utilizing alternatively two silicon PIN photodiodes, directly irradiated by the x-ray beam. Both were operated at room temperature, with low bias, so avoiding the drawbacks presented by photomultiplier tubes and germanium detectors. The energy calibration of the system was performed with X- and gamma-emitter radioactive sources, which makes the method absolute. Each kVp value was determined by means of a linear regression in the end of the spectrum, to give, simultaneously, a good fit of the straight line to the experimental data and a low standard deviation for the kVp value. Results of the measurements carried out with an x-ray tube connected to a three-phase generator, using additional filtration between 1.5 and 4.0 mm of Cu, are presented. This filtration was used in order to minimize the contribution of low energy photons and to reduce pulse pile-up. Errors determined for the values of kVp are between 0.06 and 0.16 kV, in the potential range from 50 to 100 kV. As an example, the methodology has been applied in the verification of the secondary calibration of a voltage divider, utilized, by its turn, in the tertiary calibration of noninvasive kVp meters. All intrinsic sources of errors involved in the process are discussed and evaluated.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11128315     DOI: 10.1118/1.1318222

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Experimental and Monte Carlo-simulated spectra of standard mammography-quality beams.

Authors:  M G David; E J Pires; M A Bernal; J G Peixoto; C E Dealmeida
Journal:  Br J Radiol       Date:  2011-10-18       Impact factor: 3.039

2.  Possible use of CdTe detectors in kVp monitoring of diagnostic x-ray tubes.

Authors:  M Krmar; N Bucalović; M Baucal; N Jovančević
Journal:  Nucl Instrum Methods Phys Res A       Date:  2010-10-01       Impact factor: 1.455

3.  Direct measurement of mammographic X-ray spectra with a digital CdTe detection system.

Authors:  Leonardo Abbene; Gaetano Gerardi; Fabio Principato; Stefano Del Sordo; Giuseppe Raso
Journal:  Sensors (Basel)       Date:  2012-06-18       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.