Literature DB >> 11127664

The Frank Stinchfield Award. Influence of cement technique on the interface strength of femoral components.

M F Shepard1, J M Kabo, J R Lieberman.   

Abstract

The optimal surface finish for polymethylmethacrylate cemented femoral components remains controversial. Concerns about early debonding of the prosthesis-cement interface have led surgeons to use roughened surfaces to enhance the cement-prosthesis bond. However, loosening of roughened stems is associated with the generation of excessive wear debris. The purpose of the current study was to determine whether the time to cementation influenced the cement-prosthesis bond of four roughened cobalt chrome surfaces (60 grit-blasted, 10 grit-blasted, 10 grit-blasted with polymethylmethacrylate precoating, glass bead-blasted) and one polished cobalt chrome surface. Fixation strength was assessed using mechanical pushout and tensile testing. Roughened and polymethylmethacrylate precoated surfaces had significantly greater tensile and shear strengths at early cementation times compared with polished surfaces. However, roughened components had significant decreases in tensile and shear strengths as cementation time increased from 2 to 4 minutes and 2 to 6 minutes. In contrast, tensile and shear strengths for the polished surface were significantly lower than for the roughened surfaces and did not change with longer cementation times. When using a roughened or precoated cemented femoral component, the surgeon should consider cementing earlier with wetter cement to maximize the cement-prosthesis bond. When implanting a polished femoral component, it is preferable that the cement is doughy, because the cement-prosthesis bond is not influenced by the wetness of the cement and it is easier to maintain the orientation of the femoral component.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11127664     DOI: 10.1097/00003086-200012000-00004

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  2 in total

1.  Timing of femoral prosthesis insertion during cemented arthroplasty: cement curing and static mechanical strength in an in vivo model.

Authors:  Stephen Hunt; Craig Stone; Shane Seal
Journal:  Can J Surg       Date:  2011-02       Impact factor: 2.089

2.  Comparative retrieval analysis of a novel anatomic tibial tray backside: alterations in tibial component design and surface coating can increase cement adhesions and surface roughness.

Authors:  Dominic T Mathis; Joshua Schmidli; Felix Amsler; Johann Henckel; Harry Hothi; Alister Hart; Michael T Hirschmann
Journal:  BMC Musculoskelet Disord       Date:  2022-05-19       Impact factor: 2.562

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.