Literature DB >> 11127606

Investigation of a solid-state detector for advanced computed tomography.

J Hsieh1, O E Gurmen, K F King.   

Abstract

Utilization of solid-state detectors for computed tomography (CT) has been the focus of many studies. Previous phantom and clinical experiments have shown that one of the important performance parameters for the solid-state detector is the primary speed and afterglow. In this paper, we present a detailed investigation on the signal decay characteristics of the HiLight (GE Medical Systems, Milwaukee, WI) scintillating detector. The detector primary speed and afterglow are modeled by a multiexponential function and fully characterized by a set of time constants and relative strengths. The sensitivity of these parameters to X-ray photon energy, detector aging, and radiation exposure is then established and analyzed. No statistically significant variation is observed in these parameters due to changes in the above external variables. The impact of various decay time constants on CT image quality, such as spatial resolution, noise, and artifacts, is subsequently illustrated with computer simulations and phantom experiments. Finally, an algorithmic correction scheme is derived to compensate for detector afterglow. The correction scheme employs a recursive filter to remove adverse effects of the detector decay on image quality. Experimental results have shown that the correction scheme successfully restores system spatial resolution, produces a more homogeneous noise pattern, and eliminates ring-band image artifacts due to detector afterglow. The effectiveness and robustness of the correction scheme are demonstrated by extensive phantom and clinical experiments.

Mesh:

Year:  2000        PMID: 11127606     DOI: 10.1109/42.887840

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Comparing implementations of penalized weighted least-squares sinogram restoration.

Authors:  Peter Forthmann; Thomas Koehler; Michel Defrise; Patrick La Riviere
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

2.  Improved tomographic reconstructions using adaptive time-dependent intensity normalization.

Authors:  Valeriy Titarenko; Sofya Titarenko; Philip J Withers; Francesco De Carlo; Xianghui Xiao
Journal:  J Synchrotron Radiat       Date:  2010-07-22       Impact factor: 2.616

3.  Effect of detector lag on CT noise power spectra.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

4.  Investigation into the optimal linear time-invariant lag correction for radar artifact removal.

Authors:  Jared Starman; Josh Star-Lack; Gary Virshup; Edward Shapiro; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

Review 5.  Spectral Computed Tomography: Fundamental Principles and Recent Developments.

Authors:  Aaron So; Savvas Nicolaou
Journal:  Korean J Radiol       Date:  2020-09-10       Impact factor: 3.500

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.