Literature DB >> 11126253

The "lung point": an ultrasound sign specific to pneumothorax.

D Lichtenstein1, G Mezière, P Biderman, A Gepner.   

Abstract

OBJECTIVE: We studied an ultrasound sign, the fleeting appearance of a lung pattern (lung sliding or pathologic comet-tail artifacts) replacing a pneumothorax pattern (absent lung sliding plus exclusive horizontal lines) in a particular location of the chest wall. This sign was called the "lung point".
DESIGN: Prospective study.
SETTING: The medical ICU of a university-affiliated teaching hospital. PATIENTS: The "lung point" was sought in 66 consecutive cases of proven pneumothorax analyzable using ultrasound--including 8 radio-occult cases diagnosed by means of CT and in 233 consecutive hemithoraces studied by CT and free of pneumothorax-- including 17 cases where pneumothorax was suspected.
RESULTS: The "lung point" was observed in 44 of 66 cases of pneumothorax (including 6 of 8 radio-occult cases) and in no case in the control group. The location of this sign roughly correlated with the radiological size of the pneumothorax. The "lung point" therefore had an overall sensitivity of 66 % (75 % in the case of radio-occult pneumothorax alone) and a specificity of 100%.
CONCLUSION: The presence of a "lung point" allows positive diagnosis of pneumothorax at the bedside using ultrasound.

Entities:  

Mesh:

Year:  2000        PMID: 11126253     DOI: 10.1007/s001340000627

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  112 in total

Review 1.  Pediatric chest ultrasound: a practical approach.

Authors:  Mougnyan Cox; Michalle Soudack; Daniel J Podberesky; Monica Epelman
Journal:  Pediatr Radiol       Date:  2017-08-04

Review 2.  International evidence-based recommendations for point-of-care lung ultrasound.

Authors:  Giovanni Volpicelli; Mahmoud Elbarbary; Michael Blaivas; Daniel A Lichtenstein; Gebhard Mathis; Andrew W Kirkpatrick; Lawrence Melniker; Luna Gargani; Vicki E Noble; Gabriele Via; Anthony Dean; James W Tsung; Gino Soldati; Roberto Copetti; Belaid Bouhemad; Angelika Reissig; Eustachio Agricola; Jean-Jacques Rouby; Charlotte Arbelot; Andrew Liteplo; Ashot Sargsyan; Fernando Silva; Richard Hoppmann; Raoul Breitkreutz; Armin Seibel; Luca Neri; Enrico Storti; Tomislav Petrovic
Journal:  Intensive Care Med       Date:  2012-03-06       Impact factor: 17.440

Review 3.  [Lung ultrasound in acute and critical care medicine].

Authors:  P M Zechner; A Seibel; G Aichinger; M Steigerwald; K Dorr; P Scheiermann; S Schellhaas; C Cuca; R Breitkreutz
Journal:  Anaesthesist       Date:  2012-07       Impact factor: 1.041

Review 4.  Sonographic diagnosis of pneumothorax.

Authors:  Giovanni Volpicelli
Journal:  Intensive Care Med       Date:  2010-11-20       Impact factor: 17.440

5.  Value of high-resolution ultrasound in detecting a pneumothorax.

Authors:  Myung Jin Chung; Jin Mo Goo; Jung-Gi Im; Jae Min Cho; Sung Bum Cho; Seog Joon Kim
Journal:  Eur Radiol       Date:  2004-12-18       Impact factor: 5.315

Review 6.  Lung ultrasound in pediatric radiology - cons.

Authors:  Paolo Tomà
Journal:  Pediatr Radiol       Date:  2020-02-17

7.  [Ultrasound-guided central venous access in adults and children: Procedure and pathological findings].

Authors:  P Scheiermann; F H Seeger; R Breitkreutz
Journal:  Anaesthesist       Date:  2010-01       Impact factor: 1.041

8.  Risk Factors for Loss of Lung Sliding in a Medical Intensive Care Population With Acute Respiratory Failure.

Authors:  Christopher Mallow; Warren Isakow
Journal:  J Bronchology Interv Pulmonol       Date:  2019-04

9.  [Introduction of Prehospital Emergency Ultrasound into an Emergency Medical Service Area].

Authors:  C Weilbach; A Kobiella; N Rahe-Meyer; K Johanning
Journal:  Anaesthesist       Date:  2016-12-09       Impact factor: 1.041

10.  First-line sonographic diagnosis of pneumothorax in major trauma: accuracy of e-FAST and comparison with multidetector computed tomography.

Authors:  Stefania Ianniello; Vincenza Di Giacomo; Barbara Sessa; Vittorio Miele
Journal:  Radiol Med       Date:  2014-01-28       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.