Literature DB >> 11110028

Automated in-tube solid-phase microextraction coupled with liquid chromatography-electrospray ionization mass spectrometry for the determination of selected benzodiazepines.

H Yuan1, Z Mester, H Lord, J Pawliszyn.   

Abstract

A simple, rapid, and sensitive method, which allowed us to simultaneously determine seven benzodiazepines (diazepam, nordiazepam, temazepam, oxazepam, 7-aminoflunitrazepam, N-desmethylflunitrazepam, and clonazepam) in buffer solution and in urine and serum samples, was investigated by automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS). In-tube SPME, in which the analytes were extracted from the sample directly into an open tubular capillary column by repeated draw/eject cycles of sample solution, is an extraction technique for organic compounds in aqueous samples. The separation of benzodiazepines was carried out under ion-suppressed reversed-phase conditions by using methanol/50mM ammonium acetate in water (60:40) as a mobile phase with a Supelco LC-18 column. The optimal extraction condition was 10 draw/eject cycles of 30 mL of sample in 100mM Tris-HCl (pH 8.5) at a flow rate of 0.3 mL/min using a piece of 60-cm length Supelco-Q plot capillary column as the extraction capillary. The quantitative study was explored by operating in selected-ion monitoring (SIM) mode. The calibration curves were linear in the range from 0.5 ng/mL or 2 ng/mL to 500 ng/mL. The detection limits were from 0.02 ng/mL to 2 ng/mL. At the optimized capillary and fragmentor voltages, the characteristic ions for each compound clearly showed up in the spectra and it is possible to use the LC-MS to identify these compounds. The method was applied to the analysis of biological samples without interfering peaks. However, the recoveries for some of the compounds in serum samples need to be further improved.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11110028     DOI: 10.1093/jat/24.8.718

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  4 in total

1.  Breath analysis using laser spectroscopic techniques: breath biomarkers, spectral fingerprints, and detection limits.

Authors:  Chuji Wang; Peeyush Sahay
Journal:  Sensors (Basel)       Date:  2009-10-19       Impact factor: 3.576

2.  A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management.

Authors:  Chenyu Jiang; Meixiu Sun; Zhennan Wang; Zhuying Chen; Xiaomeng Zhao; Yuan Yuan; Yingxin Li; Chuji Wang
Journal:  Sensors (Basel)       Date:  2016-07-30       Impact factor: 3.576

3.  A novel technique for simultaneous determination of drugs using magnetic nanoparticles based dispersive micro-solid-phase extraction in biological fluids and wastewaters.

Authors:  Sabah Shiri; Kamal Alizadeh; Naser Abbasi
Journal:  MethodsX       Date:  2020-06-09

Review 4.  Bioanalytical HPLC Applications of In-Tube Solid Phase Microextraction: A Two-Decade Overview.

Authors:  Natalia Manousi; Paraskevas D Tzanavaras; Constantinos K Zacharis
Journal:  Molecules       Date:  2020-04-30       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.