Literature DB >> 11107086

Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair.

Y G Wolf1, B L Johnson, B B Hill, G D Rubin, T J Fogarty, C K Zarins.   

Abstract

OBJECTIVE: The purpose of this study was to compare duplex ultrasound scanning and computed tomographic (CT) angiography for postoperative imaging and surveillance after endovascular repair of abdominal aortic aneurysm (AAA).
METHODS: One hundred consecutive patients with AAA underwent endovascular (Medtronic AneuRx, stent graft) aneurysm repair and were imaged with both CT angiography and duplex ultrasound scanning at regular intervals after the procedure. Each imaging modality was evaluated for technical adequacy and for documentation of aneurysm size, endoleak, and graft patency. In concurrent scan pairs, accuracy of duplex scanning was compared with CT.
RESULTS: A total of 268 CT scans and 214 duplex scans were obtained at intervals of 1 to 30 months after endovascular aneurysm repair (mean follow-up interval, 9+/-7 months). All CT scans were technically adequate, and 198 (93%) of 214 duplex scans were technically adequate for the determination of aneurysm size, presence of endoleak, and graft patency. Concurrent (within 7 days of each other) scan pairs were obtained in 166 instances in 76 patients (1-6 per patient). The maximal transverse aneurysm sac diameter measured with both methods correlated closely (r = 0.93; P <.001) without a significant difference on paired analysis. In 92% of scans, measurements were within 5 mm of each other. Diagnosis of endoleak on both examinations correlated closely (P <.001), and compared with CT, duplex scanning had a sensitivity of 81%, a specificity of 95%, a positive predictive value of 94%, and a negative predictive value of 90%. Discordant results occurred in 8% of examinations, and in none of these was the endoleak close to the attachment sites or associated with aneurysm expansion. An endoleak was demonstrated on both tests in all eight patients who had an endoleak judged severe enough to warrant arteriography. Graft patency was documented in each instance, without discrepancy, with both modalities.
CONCLUSIONS: High-quality duplex ultrasound scanning is comparable to CT angiography for the assessment of aneurysm size, endoleak, and graft patency after endovascular exclusion of AAA.

Entities:  

Mesh:

Year:  2000        PMID: 11107086     DOI: 10.1067/mva.2000.109210

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  11 in total

Review 1.  Endoleakage after endovascular treatment of abdominal aortic aneurysms: Diagnosis, significance and treatment.

Authors:  Jafar Golzarian; David Valenti
Journal:  Eur Radiol       Date:  2006-04-11       Impact factor: 5.315

2.  Long-term follow-up of surgically excluded popliteal artery aneurysms with multi-slice CT angiography and Doppler ultrasound.

Authors:  Sebastien Deglise; Salah D Qanadli; Elena Rizzo; Nicolas Ducrey; Francesco Doenz; Claude Haller; Alban Denys; Jean-Marc Corpataux
Journal:  Eur Radiol       Date:  2006-01-17       Impact factor: 5.315

3.  Diagnosis and treatment of abdominal aortic endoleaks using color Doppler US: Two clinical cases.

Authors:  G Nano; S Stegher; A Spinazzola
Journal:  J Ultrasound       Date:  2008-11-04

4.  Analysis of multiple genetic polymorphisms in aggressive-growing and slow-growing abdominal aortic aneurysms.

Authors:  Tyler Duellman; Christopher L Warren; Jon Matsumura; Jay Yang
Journal:  J Vasc Surg       Date:  2014-05-05       Impact factor: 4.268

Review 5.  Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

Authors:  Evridiki Karanikola; Ilias Dalainas; Georgios Karaolanis; Georgios Zografos; Konstantinos Filis
Journal:  Int J Angiol       Date:  2014-09

Review 6.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09

7.  Assessment of an engineered endothelium via single-photon emission computed tomography.

Authors:  Bin Jiang; Yidi Wu; Chad R Haney; Chongwen Duan; Guillermo A Ameer
Journal:  Biotechnol Bioeng       Date:  2017-06-27       Impact factor: 4.530

Review 8.  Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis.

Authors:  Georgios I Karaolanis; Constantine N Antonopoulos; Efstratios Georgakarakos; Georgios D Lianos; Michail Mitsis; Georgios K Glantzounis; Athanasios Giannoukas; George Kouvelos
Journal:  J Clin Med       Date:  2022-06-23       Impact factor: 4.964

9.  Society for Vascular Nursing endovascular repair of abdominal aortic aneurysm updated nursing clinical practice guideline.

Authors:  Debra Kohlman-Trigoboff; Kathleen Rich; Anne Foley; Karen Fitzgerald; Dianne Arizmendi; Carolyn Robinson; Rebecca Brown; Diane Treat-Jacobson
Journal:  J Vasc Nurs       Date:  2020-05-21

Review 10.  Surveillance of patients post-endovascular aneurysm repair.

Authors:  P Sharma; C Kyriakides
Journal:  Postgrad Med J       Date:  2007-12       Impact factor: 2.401