Literature DB >> 11103189

Within-breath arterial PO2 oscillations in an experimental model of acute respiratory distress syndrome.

E M Williams1, J P Viale, R M Hamilton, H McPeak, L Sutton, C E Hahn.   

Abstract

Tidal ventilation causes within-breath oscillations in alveolar oxygen concentration, with an amplitude which depends on the prevailing ventilator settings. These alveolar oxygen oscillations are transmitted to arterial oxygen tension, PaO2, but with an amplitude which now depends upon the magnitude of venous admixture or true shunt, QS/QT. We investigated the effect of positive end-expiratory pressure (PEEP) on the amplitude of the PaO2 oscillations, using an atelectasis model of shunt. Blood PaO2 was measured on-line with an intravascular PaO2 sensor, which had a 2-4 s response time (10-90%). The magnitude of the time-varying PaO2 oscillation was titrated against applied PEEP while tidal volume, respiratory rate and inspired oxygen concentration were kept constant. The amplitude of the PaO2 oscillation, delta PaO2, and the mean PaO2 value varied with the level of PEEP applied. At zero PEEP, both the amplitude and the mean were at their lowest values. As PEEP was increased to 1.5 kPa, both delta PaO2 and the mean PaO2 increased to a maximum. Thereafter, the mean PaO2 increased but delta PaO2 decreased. Clear oscillations of PaO2 were seen even at the lowest mean PaO2, 9.5 kPa. Conventional respiratory models of venous admixture predict that these PaO2 oscillations will be reduced by the steep part of the oxyhaemoglobin dissociation curve if a constant pulmonary shunt exists throughout the whole respiratory cycle. The facts that the PaO2 oscillations occurred at all mean PaO2 values and that their amplitude increased with increasing PEEP suggest that QS/QT, in the atelectasis model, varies between end-expiration and end-inspiration, having a much lower value during inspiration than during expiration.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11103189     DOI: 10.1093/bja/85.3.456

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  13 in total

1.  Arteriovenous oscillations of the redox potential: Is the redox state influencing blood flow?

Authors:  Jaroslaw Poznanski; Pawel Szczesny; Bartosz Pawlinski; Tomasz Mazurek; Piotr Zielenkiewicz; Zdzislaw Gajewski; Leszek Paczek
Journal:  Redox Rep       Date:  2016-05-19       Impact factor: 4.412

2.  Influence of respiratory rate and end-expiratory pressure variation on cyclic alveolar recruitment in an experimental lung injury model.

Authors:  Erik K Hartmann; Stefan Boehme; Alexander Bentley; Bastian Duenges; Klaus U Klein; Amelie Elsaesser; James E Baumgardner; Matthias David; Klaus Markstaller
Journal:  Crit Care       Date:  2012-01-16       Impact factor: 9.097

3.  Intra-breath arterial oxygen oscillations detected by a fast oxygen sensor in an animal model of acute respiratory distress syndrome.

Authors:  F Formenti; R Chen; H McPeak; P J Murison; M Matejovic; C E W Hahn; A D Farmery
Journal:  Br J Anaesth       Date:  2015-01-28       Impact factor: 9.166

4.  Experimental investigation of the effect of polymer matrices on polymer fibre optic oxygen sensors and their time response characteristics using a vacuum testing chamber and a liquid flow apparatus.

Authors:  Rongsheng Chen; Federico Formenti; Hanne McPeak; Andrew N Obeid; Clive Hahn; Andrew Farmery
Journal:  Sens Actuators B Chem       Date:  2016-01       Impact factor: 7.460

Review 5.  Recent advances in understanding acute respiratory distress syndrome.

Authors:  Peter Wohlrab; Felix Kraft; Verena Tretter; Roman Ullrich; Klaus Markstaller; Klaus Ulrich Klein
Journal:  F1000Res       Date:  2018-03-05

6.  Respiratory oscillations in alveolar oxygen tension measured in arterial blood.

Authors:  Federico Formenti; Nikhil Bommakanti; Rongsheng Chen; John N Cronin; Hanne McPeak; Delphine Holopherne-Doran; Goran Hedenstierna; Clive E W Hahn; Anders Larsson; Andrew D Farmery
Journal:  Sci Rep       Date:  2017-09-06       Impact factor: 4.379

7.  Multi frequency phase fluorimetry (MFPF) for oxygen partial pressure measurement: ex vivo validation by polarographic clark-type electrode.

Authors:  Stefan Boehme; Bastian Duenges; Klaus U Klein; Volker Hartwich; Beate Mayr; Jolanda Consiglio; James E Baumgardner; Klaus Markstaller; Reto Basciani; Andreas Vogt
Journal:  PLoS One       Date:  2013-04-02       Impact factor: 3.240

8.  Injurious mechanical ventilation in the normal lung causes a progressive pathologic change in dynamic alveolar mechanics.

Authors:  Lucio A Pavone; Scott Albert; David Carney; Louis A Gatto; Jeffrey M Halter; Gary F Nieman
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

9.  A fibre optic oxygen sensor that detects rapid PO2 changes under simulated conditions of cyclical atelectasis in vitro.

Authors:  Federico Formenti; Rongsheng Chen; Hanne McPeak; Martin Matejovic; Andrew D Farmery; Clive E W Hahn
Journal:  Respir Physiol Neurobiol       Date:  2013-10-31       Impact factor: 1.931

10.  Severe hypoxemia during veno-venous extracorporeal membrane oxygenation: exploring the limits of extracorporeal respiratory support.

Authors:  Liane Brescovici Nunes; Pedro Vitale Mendes; Adriana Sayuri Hirota; Edzangela Vasconcelos Barbosa; Alexandre Toledo Maciel; Guilherme Pinto Paula Schettino; Eduardo Leite Vieira Costa; Luciano Cesar Pontes Azevedo; Marcelo Park
Journal:  Clinics (Sao Paulo)       Date:  2014-03       Impact factor: 2.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.