Literature DB >> 11103174

Bispectral analysis of the electroencephalogram does not predict responsiveness to verbal command in patients emerging from xenon anaesthesia.

T Goto1, Y Nakata, H Saito, Y Ishiguro, Y Niimi, K Suwa, S Morita.   

Abstract

The bispectral index (BIS) is derived empirically from the electroencephalogram database of patients receiving common anaesthetics, but it may not be valid for uncommon agents. Therefore, we investigated how xenon affects the BIS. Nine and 11 patients were anaesthetized with 0.8 of the minimal alveolar concentration (MAC) of isoflurane (0.92%) and xenon (56%), respectively. After the end of operation, these concentrations were decreased in decrements of 0.1 MAC (isoflurane 0.12% or xenon 7%) and each new concentration was maintained for 15 min. This was repeated until the patient first opened her eyes or squeezed the investigator's hand on command. Isoflurane and xenon at 0.8 MAC reduced the BIS to a median of 40 (range 36-53) and 36 (30-61), respectively. With decreasing concentrations of isoflurane, the BIS increased progressively and it reached a median of 96 (90-98) when the patients awoke. In contrast, four patients receiving xenon responded to verbal command while the BIS was below 50 [median 45 (range 41-49)]. The remaining seven patients in the xenon group awoke when their BIS was greater than 80 [median 96 (range 82-98)], but in four of them the BIS was no greater than 50 when the xenon concentration was only 0.1 MAC (7%) higher than that associated with awakening. We conclude that low BIS values (< 50) do not guarantee adequate hypnosis during xenon anaesthesia.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11103174     DOI: 10.1093/bja/85.3.359

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  7 in total

1.  Xenon offers stable haemodynamics independent of induced hypothermia after hypoxia-ischaemia in newborn pigs.

Authors:  Elavazhagan Chakkarapani; Marianne Thoresen; Xun Liu; Lars Walloe; John Dingley
Journal:  Intensive Care Med       Date:  2011-12-13       Impact factor: 17.440

Review 2.  General anesthetics and molecular mechanisms of unconsciousness.

Authors:  Stuart A Forman; Victor A Chin
Journal:  Int Anesthesiol Clin       Date:  2008

3.  ECoG spectrum changes at different xenon-isoflurane anaesthesia depths.

Authors:  Bogdan Pavel; Camelia Alexandra Acatrinei; Maria Corbu; Carmen Mihaela Denise Zahiu; Adrian Eugen Rosca; Leon Zagrean; Ana-Maria Zagrean
Journal:  Rom J Anaesth Intensive Care       Date:  2017-04

4.  Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers.

Authors:  Andria Pelentritou; Levin Kuhlmann; John Cormack; Will Woods; Jamie Sleigh; David Liley
Journal:  J Vis Exp       Date:  2018-01-13       Impact factor: 1.355

5.  Recovery index, attentiveness and state of memory after xenon or isoflurane anaesthesia: a randomized controlled trial.

Authors:  Ralph Stuttmann; Jens Jakubetz; Kati Schultz; Claudia Schäfer; Sebastian Langer; Utz Ullmann; Peter Hilbert
Journal:  BMC Anesthesiol       Date:  2010-05-07       Impact factor: 2.217

Review 6.  Anaesthetic interventions for prevention of awareness during surgery.

Authors:  Anthony G Messina; Michael Wang; Marshall J Ward; Chase C Wilker; Brett B Smith; Daniel P Vezina; Nathan Leon Pace
Journal:  Cochrane Database Syst Rev       Date:  2016-10-18

Review 7.  Monitoring the depth of anaesthesia.

Authors:  Bojan Musizza; Samo Ribaric
Journal:  Sensors (Basel)       Date:  2010-12-03       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.