Literature DB >> 11101553

Outbreak of Legionnaires' disease associated with a display whirlpool spa.

D H Benkel1, E M McClure, D Woolard, J V Rullan, G B Miller, S R Jenkins, J H Hershey, R F Benson, J M Pruckler, E W Brown, M S Kolczak, R L Hackler, B S Rouse, R F Breiman.   

Abstract

BACKGROUND: Recognized outbreaks of Legionnaires' disease (LD) are rare; when they occur, they provide opportunities to understand the epidemiology of the illness and improve prevention strategies. We investigated a population-based outbreak.
METHODS: After the confirmation of LD in October 1996 in five people in neighbouring towns in southwest Virginia, active surveillance for additional cases was undertaken. A case-control study was conducted to identify exposures associated with illness, followed by a cohort study among employees of the facility at which the source of the outbreak was located in order to assess unrecognized exposure and illness. Samples of likely sources of LD in the facility were cultured for LEGIONELLA:
RESULTS: In all, 23 laboratory-confirmed cases of LD were eventually identified. Of the 15 cases in the case-control study, 14 (93%) reported visiting a home-improvement store, compared with 12 (27%) of 45 controls (matched odds ratio [MOR] = 23.3; 95% CI : 3-182). Among home-improvement centre patrons, 10 (77%) of 13 cases questioned recalled either visiting or walking by a display whirlpool spa, compared with 3 (25%) of 12 controls (MOR = 5.5; 95% CI : 0.7-256.0). Two cases' sputum isolates were an exact match, by monoclonal antibody subtyping and arbitrarily primed polymerase chain reaction, to a whirlpool spa filter isolate from the store. Employees reporting more exposure to the display spas were more likely to report symptoms of LD or to have an elevated titre.
CONCLUSIONS: This investigation shows that LD can be transmitted from a whirlpool spa used for display only, and highlights the need for minimizing the risk of transmission of LD from all water-filled spas. Key messages This paper describes an investigation of a population-based outbreak of Legionnaires' disease (LD). A case-control study first identified a home-improvement store as the likely source of the outbreak. An environmental investigation later confirmed that finding, as two cases' sputum isolates were an exact match, by monoclonal antibody subtyping and arbitrarily primed polymerase chain reaction, to a whirlpool spa filter isolate from the store. The spa was intended and used for display only.

Entities:  

Mesh:

Year:  2000        PMID: 11101553     DOI: 10.1093/ije/29.6.1092

Source DB:  PubMed          Journal:  Int J Epidemiol        ISSN: 0300-5771            Impact factor:   7.196


  15 in total

1.  Infectious Diseases Society of America/American Thoracic Society consensus guidelines on the management of community-acquired pneumonia in adults.

Authors:  Lionel A Mandell; Richard G Wunderink; Antonio Anzueto; John G Bartlett; G Douglas Campbell; Nathan C Dean; Scott F Dowell; Thomas M File; Daniel M Musher; Michael S Niederman; Antonio Torres; Cynthia G Whitney
Journal:  Clin Infect Dis       Date:  2007-03-01       Impact factor: 9.079

Review 2.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

3.  Aerosolization of respirable droplets from a domestic spa pool and the use of MS-2 coliphage and Pseudomonas aeruginosa as markers for Legionella pneumophila.

Authors:  Ginny Moore; Matthew Hewitt; David Stevenson; Jimmy T Walker; Allan M Bennett
Journal:  Appl Environ Microbiol       Date:  2014-11-07       Impact factor: 4.792

4.  Increased rainfall is associated with increased risk for legionellosis.

Authors:  L A Hicks; C E Rose; B S Fields; M L Drees; J P Engel; P R Jenkins; B S Rouse; D Blythe; A P Khalifah; D R Feikin; C G Whitney
Journal:  Epidemiol Infect       Date:  2006-11-23       Impact factor: 2.451

5.  Estimation of minimum infection rates with Legionella pneumophila in an exposed population.

Authors:  H C Boshuizen; N J D Nagelkerke; J W Den Boer; H De Melker; J F P Schellekens; M F Peeters; H Van Vliet; M A E Conyn-Van Spaendonck
Journal:  Epidemiol Infect       Date:  2005-10-20       Impact factor: 2.451

Review 6.  Improving outcomes of elderly patients with community-acquired pneumonia.

Authors:  Félix Gutiérrez; Mar Masiá
Journal:  Drugs Aging       Date:  2008       Impact factor: 3.923

Review 7.  Legionella and Legionnaires' disease: 25 years of investigation.

Authors:  Barry S Fields; Robert F Benson; Richard E Besser
Journal:  Clin Microbiol Rev       Date:  2002-07       Impact factor: 26.132

8.  Meteorological conditions and incidence of Legionnaires' disease in Glasgow, Scotland: application of statistical modelling.

Authors:  C E Dunn; B Rowlingson; R S Bhopal; P Diggle
Journal:  Epidemiol Infect       Date:  2012-06-12       Impact factor: 4.434

9.  Legionella antibodies in a Danish hospital staff with known occupational exposure.

Authors:  M Rudbeck; S Viskum; K Mølbak; S A Uldum
Journal:  J Environ Public Health       Date:  2009-05-26

Review 10.  Legionella and Biofilms-Integrated Surveillance to Bridge Science and Real-Field Demands.

Authors:  Ana Pereira; Ana Rosa Silva; Luis F Melo
Journal:  Microorganisms       Date:  2021-06-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.