Literature DB >> 11093179

Alkali- and heat-treated porous titanium for orthopedic implants.

S Nishiguchi1, H Kato, M Neo, M Oka, H M Kim, T Kokubo, T Nakamura.   

Abstract

This study was carried out to investigate the effects of the alkali and heat treatments on the bone-bonding behavior of porous titanium implants. Porous titanium implants had a 4.6 mm solid core and a 0.7 mm thick porous outer layer using pure titanium plasma-spray technique. Three types of porous implants were prepared from these pieces: 1.control implant (CL implant) as manufactured 2.AW-glass ceramic bottom-coated implant (AW implant) in which AW-glass ceramic was coated on only the bottom of the pore of the implant 3.alkali- and heat-treated implant (AH implant), where implants were immersed in 5 mol/L NaOH solution at 60 degrees C for 24 h and subsequently heated at 600 degrees C for 1 h. The implants were inserted into bilateral femora of six dogs hemi-transcortically in a randomized manner. At 4 weeks, push-out tests revealed that the mean shear strengths of the CL, AW, and AH implants were about 10.8, 12.7, and 15.0 MPa, respectively. At 12 weeks there was no significant difference between the bonding strengths of the three types of the porous implants (16.0-16.7 MPa). Histologically and histomorphologically, direct bone contact with the implant surface was significantly higher in the AH implants than the CL and AW implants both at 4 and 12 weeks. Thus, the higher bonding strength between bone and alkali- and heat-treated titanium implants was attributed to the direct bonding between bone and titanium surface. In conclusion, alkali and heat treatments can provide porous titanium implants with earlier stable fixation. Copyright 2000 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11093179     DOI: 10.1002/1097-4636(200102)54:2<198::aid-jbm6>3.0.co;2-7

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  19 in total

Review 1.  Surface treatments and roughness properties of Ti-based biomaterials.

Authors:  Andrea Bagno; Carlo Di Bello
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

2.  Design of dental implants, influence on the osteogenesis and fixation.

Authors:  Luana M R Vasconcellos; Marize V Oliveira; Mário L A Graça; Luis G O Vasconcellos; Carlos A A Cairo; Yasmin R Carvalho
Journal:  J Mater Sci Mater Med       Date:  2008-03-18       Impact factor: 3.896

Review 3.  Biomimetic systems for hydroxyapatite mineralization inspired by bone and enamel.

Authors:  Liam C Palmer; Christina J Newcomb; Stuart R Kaltz; Erik D Spoerke; Samuel I Stupp
Journal:  Chem Rev       Date:  2008-11       Impact factor: 60.622

4.  In vivo evaluation of titanium implants coated with bioactive glass by pulsed laser deposition.

Authors:  Jacinto P Borrajo; Julia Serra; Pío González; Betty León; Fernando M Muñoz; M López
Journal:  J Mater Sci Mater Med       Date:  2007-06-14       Impact factor: 3.896

5.  Functionalization of titanium based metallic biomaterials for implant applications.

Authors:  Rahul Bhola; Fengyun Su; Catherine E Krull
Journal:  J Mater Sci Mater Med       Date:  2011-04-08       Impact factor: 3.896

6.  A superhydrophilic titanium implant functionalized by ozone gas modulates bone marrow cell and macrophage responses.

Authors:  Riki Toita; Kanji Tsuru; Kunio Ishikawa
Journal:  J Mater Sci Mater Med       Date:  2016-06-25       Impact factor: 3.896

Review 7.  Bioactive metals: preparation and properties.

Authors:  T Kokubo; H M Kim; M Kawashita; T Nakamura
Journal:  J Mater Sci Mater Med       Date:  2004-02       Impact factor: 3.896

8.  The influence of scaffold material on chondrocytes under inflammatory conditions.

Authors:  Heenam Kwon; Lin Sun; Dana M Cairns; Roshni S Rainbow; Rucsanda C Preda; David L Kaplan; Li Zeng
Journal:  Acta Biomater       Date:  2013-01-16       Impact factor: 8.947

9.  Tensile force testing of optimized coin-shaped titanium implant attachment kinetics in the rabbit tibiae.

Authors:  Hans Jacob Rønold; Jan Eirik Ellingsen; Ståle Petter Lyngstadaas
Journal:  J Mater Sci Mater Med       Date:  2003-10       Impact factor: 3.896

10.  Osseous integration in porous tantalum implants.

Authors:  Christos G Paganias; George A Tsakotos; Stephanos D Koutsostathis; George A Macheras
Journal:  Indian J Orthop       Date:  2012-09       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.