Measurement of parameters of polarization in the living human eye using imaging polarimetry.

J M Bueno1.   

Abstract

An imaging polarimeter using liquid-crystal variable retarders (Bueno, J. M., Artal, P. (1999). Double-pass imaging polarimetry in the human eye. Optics Letters, 24, 64-66) has been used to study the parameters of polarization in the living human eye. Retardation introduced by birefringent structures of the eye has been calculated by using a spatially resolved collection of Mueller matrices obtained from series of 16 double-pass retinal images. Results for images with a 2-mm pupil diameter show that although the retardation introduced by the eye in a double-pass varies among individuals, at the central cornea the slow axis is directed along the upper-temporal to lower-nasal line and the ellipticity is close to zero, which indicates the presence of linear birefringence. As pupil size increased, the measured retardation also increased, while ocular birefringence remained linear and azimuthal angle changed without a clear tendency.

Entities:  

Mesh:

Year:  2000        PMID: 11090671     DOI: 10.1016/s0042-6989(00)00220-0

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  7 in total

1.  Improved contrast of subretinal structures using polarization analysis.

Authors:  Stephen A Burns; Ann E Elsner; Mariane B Mellem-Kairala; Ruthanne B Simmons
Journal:  Invest Ophthalmol Vis Sci       Date:  2003-09       Impact factor: 4.799

2.  Imaging polarimetry in central serous chorioretinopathy.

Authors:  Masahiro Miura; Ann E Elsner; Anke Weber; Michael C Cheney; Masahiro Osako; Masahiko Usui; Takuya Iwasaki
Journal:  Am J Ophthalmol       Date:  2005-12       Impact factor: 5.258

3.  Dual electro-optical modulator polarimeter based on adaptive optics scanning laser ophthalmoscope.

Authors:  Hongxin Song; Xiaofeng Qi; Weiyao Zou; Zhangyi Zhong; Stephen A Burns
Journal:  Opt Express       Date:  2010-10-11       Impact factor: 3.894

4.  Integrated Mueller-matrix near-infrared imaging and point-wise spectroscopy improves colonic cancer detection.

Authors:  Jianfeng Wang; Wei Zheng; Kan Lin; Zhiwei Huang
Journal:  Biomed Opt Express       Date:  2016-03-03       Impact factor: 3.732

5.  Mueller matrix retinal imager with optimized polarization conditions.

Authors:  K M Twietmeyer; R A Chipman; A E Elsner; Y Zhao; D VanNasdale
Journal:  Opt Express       Date:  2008-12-22       Impact factor: 3.894

Review 6.  Adaptive optics imaging of the human retina.

Authors:  Stephen A Burns; Ann E Elsner; Kaitlyn A Sapoznik; Raymond L Warner; Thomas J Gast
Journal:  Prog Retin Eye Res       Date:  2018-08-27       Impact factor: 21.198

7.  Imaging shear stress distribution and evaluating the stress concentration factor of the human eye.

Authors:  S Joseph Antony
Journal:  Sci Rep       Date:  2015-03-10       Impact factor: 4.379