Literature DB >> 11084124

Assessment of intestinal viability using a non-contact laser tissue blood flowmeter.

M Ando1, M Ito, Z Nihei, K Sugihara.   

Abstract

BACKGROUND: Intraoperative assessment of small intestinal viability following ischemic insult from arterial occlusion has remained difficult. The purpose of the present study was to assess the applicability of non-contact tissue blood flowmeter (NCLBF) with regard to intraoperative assessment of intestinal viability.
METHODS: Using the ischemia-reperfusion model of rabbits, the relationship between the records of NCLBF, pulse oximetry (PO), and histological grade and the comparison of accuracy of intestinal viability among NCLBF, PO, and fluorescein (FL) were examined.
RESULTS: There was a significant relationship between NCLBF and the histological grade (coefficient-0.80, P <0.0001); however, PO was not related. The accuracy and sensitivity of bowel viability of NCLBF (76%, 88%) were better than those of PO (58%, 23%) and FL (48%, 4%), respectively (P <0.001).
CONCLUSIONS: NCLBF is useful to assess intestinal viability, suggesting the possibility of clinical use.

Entities:  

Mesh:

Year:  2000        PMID: 11084124     DOI: 10.1016/s0002-9610(00)00444-x

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  6 in total

1.  Predicting the survival of experimental ischaemic small bowel using intraoperative near-infrared fluorescence angiography.

Authors:  A Matsui; J H Winer; R G Laurence; J V Frangioni
Journal:  Br J Surg       Date:  2011-09-27       Impact factor: 6.939

2.  Visual enhancement of laparoscopic partial nephrectomy with 3-charge coupled device camera: assessing intraoperative tissue perfusion and vascular anatomy by visible hemoglobin spectral response.

Authors:  Nicole J Crane; Suzanne M Gillern; Kambiz Tajkarimi; Ira W Levin; Peter A Pinto; Eric A Elster
Journal:  J Urol       Date:  2010-08-17       Impact factor: 7.450

3.  Validation of IC-VIEW fluorescence videography in a rabbit model of mesenteric ischaemia and reperfusion.

Authors:  C Toens; C J Krones; U Blum; V Fernandez; J Grommes; F Hoelzl; M Stumpf; U Klinge; V Schumpelick
Journal:  Int J Colorectal Dis       Date:  2005-08-19       Impact factor: 2.571

4.  Contrast enhancement for in vivo visible reflectance imaging of tissue oxygenation.

Authors:  Nicole J Crane; Zachary D Schultz; Ira W Levin
Journal:  Appl Spectrosc       Date:  2007-08       Impact factor: 2.388

5.  How to assess intestinal viability during surgery: A review of techniques.

Authors:  Linas Urbanavičius; Piet Pattyn; Dirk Van de Putte; Donatas Venskutonis
Journal:  World J Gastrointest Surg       Date:  2011-05-27

6.  Non-invasive monitoring of tissue oxygenation during laparoscopic donor nephrectomy.

Authors:  Nicole J Crane; Peter A Pinto; Douglas Hale; Frederick A Gage; Doug Tadaki; Allan D Kirk; Ira W Levin; Eric A Elster
Journal:  BMC Surg       Date:  2008-04-17       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.