Literature DB >> 11079489

Quantitative comparison of automatic and interactive methods for MRI-SPECT image registration of the brain based on 3-dimensional calculation of error.

T Pfluger1, C Vollmar, A Wismüller, S Dresel, F Berger, P Suntheim, G Leinsinger, K Hahn.   

Abstract

UNLABELLED: A wide range of techniques for registration of medical images has been devised in recent years. The aim of this study is to quantify the overall spatial registration error of 3 different methods for image registration: interactive matching, surface matching, and uniformity index matching as described by Woods.
METHODS: MRI and ethylcysteinate dimer-SPECT images of the brain were registered for 15 patients. The matching error was assessed by determining intra- and interobserver variability of registrations. Quantification of the registration error was based on the mean spatial distance of 5000 voxels between 2 image positions. The mean position after repeated registrations in each patient was used as the gold standard. To evaluate the coherence of the 3 different registration methods, intermethod variability was determined.
RESULTS: Interactive matching showed an intraobserver/interobserver variability of 1.5+/-0.3 mm/1.6+/-0.3 mm (mean +/- SD). The time demand for this method was 11+/-5 min. Surface matching revealed a variability of 2.6+/-1.1 mm/3.8+/-1.0 mm and a time demand of 26+/-12 min. Reproducibility of Woods' algorithm was 2.2+/-0.8 mm with a time demand of 9+/-3 min. In 4 of the 15 cases, Woods' method failed. The mean deviation between all 3 methods was 2.3+/-0.8 mm.
CONCLUSION: With a suitable user interface, interactive matching had the lowest registration error. The influence of subjectivity was shown to be negligible. Therefore, interactive matching is our preferred technique for image fusion of the brain.

Entities:  

Mesh:

Year:  2000        PMID: 11079489

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  11 in total

1.  A versatile functional-anatomic image fusion method for volume data sets.

Authors:  M E Noz; G Q Maguire; M P Zeleznik; E L Kramer; F Mahmoud; J Crafoord
Journal:  J Med Syst       Date:  2001-10       Impact factor: 4.460

2.  Evaluation of a semiautomatic 3D fusion technique applied to molecular imaging and MRI brain/frame volume data sets.

Authors:  R J T Gorniak; E L Kramer; G Q Maguire; M E Noz; C J Schettino; M P Zeleznik
Journal:  J Med Syst       Date:  2003-04       Impact factor: 4.460

3.  A hybrid strategy to integrate surface-based and mutual-information-based methods for co-registering brain SPECT and MR images.

Authors:  Yuan-Lin Liao; Yung-Nien Sun; Wan-Yuo Guo; Yuan-Hwa Chou; Jen-Chuen Hsieh; Yu-Te Wu
Journal:  Med Biol Eng Comput       Date:  2010-12-30       Impact factor: 2.602

4.  A robust coregistration method for in vivo studies using a first generation simultaneous PET/MR scanner.

Authors:  Thomas S C Ng; Daniel Procissi; Yibao Wu; Russell E Jacobs
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

5.  Automated alignment of perioperative MRI scans: A technical note and application in pediatric epilepsy surgery.

Authors:  Richard Beare; Joseph Yuan-Mou Yang; Wirginia J Maixner; A Simon Harvey; Michael J Kean; Vicki A Anderson; Marc L Seal
Journal:  Hum Brain Mapp       Date:  2016-05-16       Impact factor: 5.038

6.  [Neuroimaging of epilepsies].

Authors:  C Vollmar; C la Fougère
Journal:  Nervenarzt       Date:  2012-02       Impact factor: 1.214

7.  [18F]FDG imaging of head and neck tumours: comparison of hybrid PET and morphological methods.

Authors:  S Dresel; J Grammerstorff; K Schwenzer; K Brinkbäumer; R Schmid; T Pfluger; K Hahn
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-05-09       Impact factor: 9.236

8.  Acceptance test of a commercially available software for automatic image registration of computed tomography (CT), magnetic resonance imaging (MRI) and 99mTc-methoxyisobutylisonitrile (MIBI) single-photon emission computed tomography (SPECT) brain images.

Authors:  Gianfranco Loi; Marco Dominietto; Irene Manfredda; Eleonora Mones; Alessandro Carriero; Eugenio Inglese; Marco Krengli; Marco Brambilla
Journal:  J Digit Imaging       Date:  2008-09       Impact factor: 4.056

9.  Small-animal PET imaging of amyloid-beta plaques with [11C]PiB and its multi-modal validation in an APP/PS1 mouse model of Alzheimer's disease.

Authors:  André Manook; Behrooz H Yousefi; Antje Willuweit; Stefan Platzer; Sybille Reder; Andreas Voss; Marc Huisman; Markus Settles; Frauke Neff; Joachim Velden; Michael Schoor; Heinz von der Kammer; Hans-Jürgen Wester; Markus Schwaiger; Gjermund Henriksen; Alexander Drzezga
Journal:  PLoS One       Date:  2012-03-09       Impact factor: 3.240

10.  Reproducibility of interactive registration of 3D CT and MR pediatric treatment planning head images.

Authors:  J Vaarkamp
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.