Literature DB >> 11071074

Comparative multicentre study of a panel of thyroid tests using different automated immunoassay platforms and specimens at high risk of antibody interference.

J Martel1, N Després, C E Ahnadi, J F Lachance, J E Monticello, G Fink, A Ardemagni, G Banfi, J Tovey, P Dykes, R John, J Jeffery, A M Grant.   

Abstract

The introduction of automation for immunoassays in recent years has brought about important and evident improvements in assay precision. Increasing standardization and comparability between platforms should enable the development of clinical guidelines and diagnostic algorithms for appropriate clinical decision making. A continuing source of variation between different automated immunoassay platforms is the sporadic effect of interfering antibodies or substances, thus causing aberrant results not supporting the patient's clinical status. The aim of this study was to describe current thyroid panel variation between automated immunoassay platforms including population specimens at risk of antibody interference. A multisite design with laboratories in three different countries using four different automated immunoassay platforms (Roche-Boehringer Mannheim Elecsys (Italy), Roche-Boehringer Mannheim ES300 (Wales), Bayer Immuno 1 and the Bayer ACS:180 evaluated the thyroid panel of thyrotropin (TSH), triiodothyromine (T3), free thyroxine (FT4) and free triiodothyronine (FT3). A common set of 158 randomly selected patient samples of non-thyroid and thyroid disorders, with and without treatment, was tested. Included were 62 patient samples at risk for endogenous antibody interference with high antimicrosomal antibody, anti-TSH receptor antibody and increased rheumatoid factor sub-populations. Across all controls and between platforms, precision measurements were comparable and varied between 0.7% and 12.8% for TSH, 2.8% and 13% for FT4, 1.8% and 10.5% for FT3 and 3.1% and 16% for T3 assay. Acceptable correlation and reproducibility were found between the three Bayer Immuno 1 platforms at each country's site with all four thyroid panel assays demonstrating r-values of 0.989 to 1.000 and slopes of 0.915 to 1.078. Comparisons between the different platforms showed acceptable correlation for all thyroid panel assays. Specimens containing rheumatoid factor were associated with a significantly increased variation between systems for the FT4 and FT3 assays (p < 0.01). This effect did not appear to be selective for a given platform. For specimens with raised autoimmune antibodies and therefore at risk of assay antibody interference, no variation could be observed between the platforms.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11071074     DOI: 10.1515/CCLM.2000.112

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  11 in total

Review 1.  Thyroid function testing in pregnancy and thyroid disease: trimester-specific reference intervals.

Authors:  Offie P Soldin
Journal:  Ther Drug Monit       Date:  2006-02       Impact factor: 3.681

2.  Gestation-specific thyroxine and thyroid stimulating hormone levels in the United States and worldwide.

Authors:  Offie P Soldin; Danielle Soldin; Marisol Sastoque
Journal:  Ther Drug Monit       Date:  2007-10       Impact factor: 3.681

Review 3.  Thyrotropin isoforms: implications for thyrotropin analysis and clinical practice.

Authors:  Joshua M Estrada; Danielle Soldin; Timothy M Buckey; Kenneth D Burman; Offie P Soldin
Journal:  Thyroid       Date:  2013-12-13       Impact factor: 6.568

Review 4.  Thyroid hormone testing by tandem mass spectrometry.

Authors:  Offie P Soldin; Steven J Soldin
Journal:  Clin Biochem       Date:  2010-08-04       Impact factor: 3.281

5.  Interferences in immunoassay.

Authors:  Jill Tate; Greg Ward
Journal:  Clin Biochem Rev       Date:  2004-05

6.  Tandem mass spectrometry as a novel tool for elucidating pituitary-thyroid relationships.

Authors:  Jacqueline Jonklaas; Steven J Soldin
Journal:  Thyroid       Date:  2008-12       Impact factor: 6.568

7.  Correlations of free thyroid hormones measured by tandem mass spectrometry and immunoassay with thyroid-stimulating hormone across 4 patient populations.

Authors:  Jacqueline Jonklaas; Natasa Kahric-Janicic; Offie P Soldin; Steven J Soldin
Journal:  Clin Chem       Date:  2009-05-21       Impact factor: 8.327

8.  Trimester-specific thyroid hormone reference ranges in Sudanese women.

Authors:  Enaam T Elhaj; Ishag Adam; Mohamed A Ahmed; Mohamed F Lutfi
Journal:  BMC Physiol       Date:  2016-10-31

9.  Avoiding Misdiagnosis Due to Antibody Interference with Serum Free Thyroxin.

Authors:  Pilar I Beato-Víbora; S Alejo-González
Journal:  Int J Endocrinol Metab       Date:  2016-11-14

10.  Pediatric reference intervals for thyroid hormone levels from birth to adulthood: a retrospective study.

Authors:  Klaus Kapelari; Christine Kirchlechner; Wolfgang Högler; Katharina Schweitzer; Irene Virgolini; Roy Moncayo
Journal:  BMC Endocr Disord       Date:  2008-11-27       Impact factor: 2.763

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.