Literature DB >> 11067791

Coronary pressure measurement to assess the hemodynamic significance of serial stenoses within one coronary artery: validation in humans.

N H Pijls1, B De Bruyne, G J Bech, F Liistro, G R Heyndrickx, H J Bonnier, J J Koolen.   

Abstract

BACKGROUND: When several stenoses are present within 1 coronary artery, the hemodynamic significance of each stenosis is influenced by the presence of the other(s), and the calculation of coronary and fractional flow reserve (CFR and FFR) for each individual stenosis is confounded. Recently, we developed and experimentally validated a method to determine the true FFR of each stenosis as it would be after the removal of the other stenosis; the true FFR can be reliably predicted by coronary pressures measured before treatment at specific locations within the coronary artery using equations accounting for stenosis interaction. The aim of the present study was to test the validity of these equations in humans. METHODS AND
RESULTS: In this study of 32 patients with 2 serial stenoses in 1 coronary artery, relevant pressures were measured before the intervention, after the treatment of 1 stenosis, and after the treatment of both stenoses. The true FFR of each stenosis (FFR(true)) was directly measured after the elimination of the other stenosis and compared with the value predicted (FFR(pred)) from the initial pressure measurements before treatment. Although the hyperemic gradient across 1 stenosis increased significantly (from 10+/-7 to 19+/-11 mm Hg after treatment of the other stenosis), FFR(pred) was close to FFR(true) in all patients (0.78+/-0.12 versus 0.78+/-0.11 mm Hg; r=0.92; Delta%=4+/-0%). Without accounting for stenosis interaction, the value of FFR for each stenosis would have been significantly overestimated (0.85+/-0.08; P:<0.01).
CONCLUSIONS: Coronary pressure measurements made by a pressure wire at maximum hyperemia provide a simple, practical method for assessing the individual hemodynamic significance of multiple stenoses within the same artery.

Entities:  

Mesh:

Year:  2000        PMID: 11067791     DOI: 10.1161/01.cir.102.19.2371

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  51 in total

Review 1.  Optimum guidance of complex PCI by coronary pressure measurement.

Authors:  Nico H J Pijls
Journal:  Heart       Date:  2004-09       Impact factor: 5.994

2.  Use of a pressure-sensing wire to detect sequential pressure gradients for ipsilateral vertebral and subclavian artery stenoses.

Authors:  Chung-Pin Liu; Yen-Hung Ling; Hsien-Li Kao
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

3.  Postprocedural resistance of the target lesion is a strong predictor of subsequent revascularization: assessment by a novel lesion-specific physiological parameter, the epicardial resistance index.

Authors:  Kazuhito Suzuki; Yukio Tsurumi; Yuji Fuda; Yasuhiro Ishii; Atsushi Takagi; Nobuhisa Hagiwara; Hiroshi Kasanuki
Journal:  Heart Vessels       Date:  2007-05-21       Impact factor: 2.037

4.  Optical coherence tomography criteria for defining functional severity of intermediate lesions: a comparative study with FFR.

Authors:  Tomasz Pawlowski; Francesco Prati; Tomasz Kulawik; Eleonora Ficarra; Jacek Bil; Robert Gil
Journal:  Int J Cardiovasc Imaging       Date:  2013-09-03       Impact factor: 2.357

5.  Fractional flow reserve-guided percutaneous coronary intervention for an intermediate stenosis complicated by a coronary-to-pulmonary artery fistula.

Authors:  Tsuyoshi Ito; Shunsuke Murai; Hiroshi Fujita; Tomomitsu Tani; Nobuyuki Ohte
Journal:  Heart Vessels       Date:  2015-02-03       Impact factor: 2.037

6.  The relationship between myocardial SPECT and fractional flow reserve: is it drifting apart?

Authors:  Michael Rees
Journal:  Int J Cardiovasc Imaging       Date:  2009-12-24       Impact factor: 2.357

7.  Characteristics of the flow velocity-pressure gradient relation in the assessment of stenoses: an in vitro study.

Authors:  K M J Marques; N Westerhof
Journal:  Neth Heart J       Date:  2008-05       Impact factor: 2.380

8.  Predicting functional significance of each stenosis in serial coronary artery stenoses: Where there is a will, there is a way.

Authors:  Mineok Chang; Bon-Kwon Koo
Journal:  Cardiol J       Date:  2019       Impact factor: 2.737

9.  A simplified formula to calculate fractional flow reserve in sequential lesions circumventing the measurement of coronary wedge pressure: The APIS-S pilot study.

Authors:  Juan Luis Gutiérrez-Chico; Carlos Cortés; Miłosz Jaguszewski; Michele Schincariol; Ignacio J Amat-Santos; Juan A Franco-Peláez; Grzegorz Żuk; Dariusz Ciećwierz; Wojciech Wojakowski; Felipe Navarro; Shengxian Tu; Borja Ibáñez
Journal:  Cardiol J       Date:  2019-07-01       Impact factor: 2.737

10.  Coronary pressure measurement based decision making for percutaneous coronary intervention.

Authors:  Kohichiro Iwasaki; Shozo Kusachi
Journal:  Curr Cardiol Rev       Date:  2009-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.