Literature DB >> 11064651

How should breathing motion be combined with other errors when drawing margins around clinical target volumes?

A L McKenzie1.   

Abstract

Geometric uncertainties in radiotherapy treatment may be accommodated by drawing an adequate margin around the clinical target volume (CTV). The width of the margin is commonly based upon the quadrature sum of the standard deviations of the contributory errors. This approach is satisfactory when the probability distributions of the component errors are Gaussian, but breathing-induced motion of the CTV is generally not Gaussian. This paper shows that the blurred dose distribution D(z) arising from a step function beam edge that is moving cyclically along the z-axis is given by D(z) = 2t/tau, where t(z) relates time to position and tau is the cycle duration. Applying this relation to realistic breathing models results in a dose distribution in which the sharp edge of the step function is still evident even after blurring caused by the motion. This suggests that breathing-induced motion should be accounted for separately, with the breathing margin added linearly to the quadrature sum of the other contributing errors.

Mesh:

Year:  2000        PMID: 11064651     DOI: 10.1259/bjr.73.873.11064651

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  8 in total

1.  Comparison of Safety Margin Generation Concepts in Image Guided Radiotherapy to Account for Daily Head and Neck Pose Variations.

Authors:  Markus Stoll; Eva Maria Stoiber; Sarah Grimm; Jürgen Debus; Rolf Bendl; Kristina Giske
Journal:  PLoS One       Date:  2016-12-29       Impact factor: 3.240

2.  Assessment and quantification of patient set-up errors in nasopharyngeal cancer patients and their biological and dosimetric impact in terms of generalized equivalent uniform dose (gEUD), tumour control probability (TCP) and normal tissue complication probability (NTCP).

Authors:  A Boughalia; S Marcie; M Fellah; S Chami; F Mekki
Journal:  Br J Radiol       Date:  2015-04-17       Impact factor: 3.039

3.  Biological impact of geometric uncertainties: what margin is needed for intra-hepatic tumors?

Authors:  Hsiang-Chi Kuo; Wen-Shan Liu; Andrew Wu; Dennis Mah; Keh-Shih Chuang; Linda Hong; Ravi Yaparpalvi; Chandan Guha; Shalom Kalnicki
Journal:  Radiat Oncol       Date:  2010-06-03       Impact factor: 3.481

4.  An alternative approach to GTV margin determination in stereotactic body radiotherapy.

Authors:  José Bea-Gilabert; M Carmen Baños-Capilla; M Ángeles García-Martínez; Enrique López-Muñoz; Luis M Larrea-Rabassa
Journal:  J Radiosurg SBRT       Date:  2019

5.  Free-breathing conformal irradiation of pancreatic cancer.

Authors:  Ignazio Solla; Sergio Zucca; Marco Possanzini; Sara Piras; Claudio Pusceddu; Sergio Porru; Gianfranco Meleddu; Paolo Farace
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

6.  Assessment of setup uncertainties for various tumor sites when using daily CBCT for more than 2200 VMAT treatments.

Authors:  Young-Kee Oh; Jong-Geun Baek; Ok-Bae Kim; Jin-Hee Kim
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

7.  Evaluation of techniques for slice sensitivity profile measurement and analysis.

Authors:  Travis C Greene; X John Rong
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

8.  Clinical experience of the importance of daily portal imaging for head and neck IMRT treatments.

Authors:  Laurence E Court; Luciant Wolfsberger; Aaron M Allen; Steven James; Roy B Tishler
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.