Literature DB >> 11055737

Application of multishot acquisition in Fourier transform mass spectrometry.

P B O'Connor1, C E Costello.   

Abstract

A new method of ion injection and trapping is discussed wherein ions are accumulated over several laser shots in the FT-ICR cell prior to detection. This allows accumulation of ion signal without accumulating noise so that the signal/noise ratio is much improved provided that the "space-charge" limit of the total number of ions in the cell is not exceeded. "In-cell" ion accumulation allows selected ion accumulation by simply sweeping unwanted ions out of the cell prior to subsequent ion trapping events and also allows shifted ion accumulations to correct for time-of-flight distortions in the ion abundance distributions.

Mesh:

Year:  2000        PMID: 11055737     DOI: 10.1021/ac0005565

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  A high pressure matrix-assisted laser desorption ion source for Fourier transform mass spectrometry designed to accommodate large targets with diverse surfaces.

Authors:  Peter B O'Connor; Bogdan A Budnik; Vera B Ivleva; Parminder Kaur; Susanne C Moyer; Jason L Pittman; Catherine E Costello
Journal:  J Am Soc Mass Spectrom       Date:  2004-01       Impact factor: 3.109

2.  Combining low and high mass ion accumulation for enhancing shotgun proteome analysis by accurate mass measurement.

Authors:  Richard L Wong; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-18       Impact factor: 3.109

3.  Quantitative proteomics and metabolomics analysis of normal human cerebrospinal fluid samples.

Authors:  Marcel P Stoop; Leon Coulier; Therese Rosenling; Shanna Shi; Agnieszka M Smolinska; Lutgarde Buydens; Kirsten Ampt; Christoph Stingl; Adrie Dane; Bas Muilwijk; Ronald L Luitwieler; Peter A E Sillevis Smitt; Rogier Q Hintzen; Rainer Bischoff; Sybren S Wijmenga; Thomas Hankemeier; Alain J van Gool; Theo M Luider
Journal:  Mol Cell Proteomics       Date:  2010-09       Impact factor: 5.911

4.  Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) imaging source coupled to a FT-ICR mass spectrometer.

Authors:  Guillaume Robichaud; Jeremy A Barry; Kenneth P Garrard; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2012-12-04       Impact factor: 3.109

5.  Laser desorption/ionization Fourier transform mass spectrometry of thin films deposited on silicon by plasma polymerization of acetylene.

Authors:  Sasa M Miladinović; Valérie De Vriendt; Scott A Robotham; Fabrizio Maseri; Stéphane Lucas; Charles L Wilkins
Journal:  J Am Soc Mass Spectrom       Date:  2009-12-03       Impact factor: 3.109

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.