Literature DB >> 11050361

Measuring spinal motion in rowers: the use of an electromagnetic device.

A M Bull1, A H McGregor.   

Abstract

OBJECTIVE: To determine whether a skin-mounted electromagnetic measurement device can be used to measure lumbar spinal motion in rowers and discriminate between variations in technique.
DESIGN: The lumbar spinal kinematics of elite level rowers were assessed with an electromagnetic device (Flock of Birds) during ergometer training using five technique variants. The system was correlated with sagittal MRI imaging of the lumbar spine and pelvis.
BACKGROUND: Rowing technique is related to performance and injury. This study sought to test a method to obtain quantitative data on the effect of changes in technique on lumbar spinal and pelvic motion.
METHODS: Lumbar spinal and pelvic motion were measured in six elite level rowers on an ergometer using normal rowing technique, three common bad technique variants, and after a 10 min piece of rowing simulating fatigue.
RESULTS: Significant differences were found between the different rowing techniques for femoral, thoraco-lumbar and lumbo-sacral flexion.
CONCLUSIONS: Kinematic parameters of spinal motion of rowers can be measured dynamically and used to quantify and discriminate between good and bad rowing styles. Relevance There is a consistent style of "good" rowing technique on an ergometer. Deviations from this technique can be measured and this will allow studies to be conducted comparing rowing styles between rowers of different standards and between different boat houses. There is potential to develop a dynamic feedback system to the rower that will assist in training and eradicate bad technique variants.

Entities:  

Mesh:

Year:  2000        PMID: 11050361     DOI: 10.1016/s0268-0033(00)00043-7

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  11 in total

1.  Trunk posture monitoring with inertial sensors.

Authors:  Wai Yin Wong; Man Sang Wong
Journal:  Eur Spine J       Date:  2008-01-15       Impact factor: 3.134

2.  Longitudinal changes in the spinal kinematics of oarswomen during step testing.

Authors:  Alison H McGregor; Zeenat S Patankar; Anthony M J Bull
Journal:  J Sports Sci Med       Date:  2007-03-01       Impact factor: 2.988

3.  A comparison of kinematics and performance measures of two rowing ergometers.

Authors:  Rebecca R Steer; Alison H McGregor; Anthony M J Bull
Journal:  J Sports Sci Med       Date:  2006-03-01       Impact factor: 2.988

4.  ASSOCIATION BETWEEN ROWING INJURIES AND THE FUNCTIONAL MOVEMENT SCREEN™ IN FEMALE COLLEGIATE DIVISION I ROWERS.

Authors:  Helen Clay; Jamie Mansell; Ryan Tierney
Journal:  Int J Sports Phys Ther       Date:  2016-06

5.  Changes in rowing technique over a routine one hour low intensity high volume training session.

Authors:  Hugh A M Mackenzie; Anthony M J Bull; Alison H McGregor
Journal:  J Sports Sci Med       Date:  2008-12-01       Impact factor: 2.988

Review 6.  Rowing Injuries in Elite Athletes: A Review of Incidence with Risk Factors and the Role of Biomechanics in Its Management.

Authors:  S Arumugam; Prakash Ayyadurai; Suresh Perumal; G Janani; Sidak Dhillon; K A Thiagarajan
Journal:  Indian J Orthop       Date:  2020-01-31       Impact factor: 1.251

Review 7.  Gait analysis using wearable sensors.

Authors:  Weijun Tao; Tao Liu; Rencheng Zheng; Hutian Feng
Journal:  Sensors (Basel)       Date:  2012-02-16       Impact factor: 3.576

8.  An alternative technical marker set for the pelvis is more repeatable than the standard pelvic marker set.

Authors:  Maedeh Borhani; Alison H McGregor; Anthony M J Bull
Journal:  Gait Posture       Date:  2013-06-19       Impact factor: 2.840

Review 9.  Injury prevention, performance and return to sport: How can science help?

Authors:  Alison H McGregor
Journal:  Chin J Traumatol       Date:  2017-03-16

10.  Soft tissue artefacts of the human back: comparison of the sagittal curvature of the spine measured using skin markers and an open upright MRI.

Authors:  Roland Zemp; Renate List; Turgut Gülay; Jean Pierre Elsig; Jaroslav Naxera; William R Taylor; Silvio Lorenzetti
Journal:  PLoS One       Date:  2014-04-18       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.