Literature DB >> 11041580

Comparison of in vivo wear between polyethylene liners articulating with ceramic and cobalt-chrome femoral heads.

C J Sychterz1, C A Engh, A M Young, R H Hopper, C A Engh.   

Abstract

At yearly intervals we compared the radiological wear characteristics of 81 alumina ceramic femoral heads with a well-matched group of 43 cobalt-chrome femoral heads. Using a computer-assisted measurement system we assessed two-dimensional penetration of the head into the polyethylene liner. We used linear regression analysis of temporal data of the penetration of the head to calculate the true rates of polyethylene wear for both groups. At a mean of seven years the true rate of wear of the ceramic group was slightly greater (0.09 mm/year, SD 0.07) than that of the cobalt-chrome group (0.07 mm/year, SD 0.04). Despite the numerous theoretical advantages of ceramic over cobalt-chrome femoral heads, the wear performance in vivo of these components was similar.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11041580     DOI: 10.1302/0301-620x.82b7.9885

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  11 in total

1.  Wear analysis of chamfered elongated acetabular cup liners.

Authors:  Hsiao-Che Lin; Tzuo-Liang Luo; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2011-12-22       Impact factor: 2.602

2.  Wear patterns of, and wear volume formulae for, cylindrically elongated acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2010-04-28       Impact factor: 2.602

3.  Long-term wear of dual mobility total hip replacement cups: explant study.

Authors:  Bertrand Boyer; Thomas Neri; Jean Geringer; Alexandre Di Iorio; Remi Philippot; Frederic Farizon
Journal:  Int Orthop       Date:  2017-06-03       Impact factor: 3.075

4.  Using a patterned microtexture to reduce polyethylene wear in metal-on-polyethylene prosthetic bearing couples.

Authors:  A Borjali; J Langhorn; K Monson; B Raeymaekers
Journal:  Wear       Date:  2017-09-22       Impact factor: 3.892

5.  Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra high molecular weight cemented polyethylene cups: a ten-year follow-up with radiostereometry.

Authors:  Jon Dahl; Per Söderlund; Bo Nivbrant; Lars Nordsletten; Stephan M Röhrl
Journal:  Int Orthop       Date:  2011-08-26       Impact factor: 3.075

6.  Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

Authors:  Yup Lee Jung; Shin-Yoon Kim
Journal:  Open Orthop J       Date:  2010-02-11

7.  A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints.

Authors:  Anthony Chyr; Mingfeng Qiu; Jared Speltz; Ronald L Jacobsen; Anthony P Sanders; Bart Raeymaekers
Journal:  Wear       Date:  2014-07-15       Impact factor: 3.892

8.  A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up.

Authors:  Shijun Wang; ShuDong Zhang; YuChi Zhao
Journal:  J Orthop Surg Res       Date:  2013-07-08       Impact factor: 2.359

9.  More than 50% reduction of wear in polyethylene liners with alumina heads compared to cobalt-chrome heads in hip replacements: a 10-year follow-up with radiostereometry in 43 hips.

Authors:  Jon Dahl; Finnur Snorrason; Lars Nordsletten; Stephan M Röhrl
Journal:  Acta Orthop       Date:  2013-06-25       Impact factor: 3.717

10.  Early catastrophic acetabular failure in Furlong total hip replacements.

Authors:  David Knox; Steven W Hamilton; Douglas Wardlaw; Peter H Gibson
Journal:  J Orthop Traumatol       Date:  2009-01-31
View more