Literature DB >> 11029160

Image-guided radiosurgery for the spine and pancreas.

M J Murphy1, J R Adler, M Bodduluri, J Dooley, K Forster, J Hai, Q Le, G Luxton, D Martin, J Poen.   

Abstract

A robotic image-guided radiosurgical system has been modified to treat extra-cranial sites using implanted fiducials and skeletal landmarks to locate the treatment targets. The system has been used to treat an artero-venous malformation in the cervical spine, a recurrent schwannoma of the thoracic spine, a metastatic adenocarcinoma of the lumbar spine, and three pancreatic cancers. During each treatment, the image guidance system monitored the position of the target site and relayed the target coordinates to the beam-pointing system at discrete intervals. The pointing system then dynamically aligned the therapy beam with the lesion, automatically compensating for shifts in target position. Breathing-related motion of the pancreas lesions was managed by coordinating beam gating with breath-holding by the patient. The system maintained alignment with the spine lesions to within +/- 0.2 mm on average, and to within +/- 1 mm for the pancreatic tumors. This experience has demonstrated the feasibility of using image-guided robotic radiosurgery outside the cranium. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2000        PMID: 11029160     DOI: 10.1002/1097-0150(2000)5:4<278::AID-IGS6>3.0.CO;2-K

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  11 in total

1.  A preliminary probe into the movement of pancreatic lesions and factors that influence it.

Authors:  Y-C Song; J-Q You; Z-Y Yuan; W Wang; X-Y Li; P Wang
Journal:  Br J Radiol       Date:  2010-06       Impact factor: 3.039

2.  Real-time prediction of tumor motion using a dynamic neural network.

Authors:  Majid Mafi; Saeed Montazeri Moghadam
Journal:  Med Biol Eng Comput       Date:  2020-01-08       Impact factor: 2.602

3.  Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: a feasibility study.

Authors:  Rajesh Regmi; D Michael Lovelock; Margie Hunt; Pengpeng Zhang; Hai Pham; Jianping Xiong; Ellen D Yorke; Karyn A Goodman; Andreas Rimner; Hassan Mostafavi; Gig S Mageras
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

4.  Stereotactic body radiotherapy for pulmonary metastases. Prognostic factors and adverse respiratory events.

Authors:  T Inoue; R-J Oh; H Shiomi; N Masai; H Miura
Journal:  Strahlenther Onkol       Date:  2013-02-20       Impact factor: 3.621

5.  On the accuracy of a moving average algorithm for target tracking during radiation therapy treatment delivery.

Authors:  Rohini George; Yelin Suh; Martin Murphy; Jeffrey Williamson; Elizabeth Weiss; Paul Keall
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

6.  Comparison of CT artifacts and image recognition of various fiducial markers including two types of thinner fiducial markers for CyberKnife treatment.

Authors:  Toshihiro Suzuki; Masahide Saito; Hiroshi Onishi; Koji Mochizuki; Kenichiro Satani; Akihiro Yamazaki; Kenichi Miura; Shinji Taka; Naoki Sano; Takafumi Komiyama; Hiroshi Takahashi
Journal:  Rep Pract Oncol Radiother       Date:  2019-12-09

Review 7.  Imaging in radiation oncology: a perspective.

Authors:  Laura A Dawson; Cynthia Ménard
Journal:  Oncologist       Date:  2010

8.  A level-wise spine registration framework to account for large pose changes.

Authors:  Yunliang Cai; Shaoju Wu; Xiaoyao Fan; Jonathan Olson; Linton Evans; Scott Lollis; Sohail K Mirza; Keith D Paulsen; Songbai Ji
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-05-10       Impact factor: 3.421

9.  Feasibility study of dual energy radiographic imaging for target localization in radiotherapy for lung tumors.

Authors:  Jie Huo; Xianfeng Zhu; Yang Dong; Zhiyong Yuan; Ping Wang; Xuemin Wang; Gang Wang; Xin-Hua Hu; Yuanming Feng
Journal:  PLoS One       Date:  2014-09-30       Impact factor: 3.240

10.  Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience.

Authors:  Zheng Chang; James Bowsher; Jing Cai; Sua Yoo; Zhiheng Wang; Justus Adamson; Lei Ren; Fang-Fang Yin
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.