Literature DB >> 11028762

Need for revisiting the concept of reference values.

J Henny1, C Petitclerc, X Fuentes-Arderiu, P H Petersen, J M Queraltó, F Schiele, G Siest.   

Abstract

The reference values concept has been adopted by health care professionals, including clinical chemists, laboratory scientists, and clinicians and simultaneously by all the official organizations in charge of the establishment of legislation. But the estimation of reference limits, and the evaluation of biological variability need to be improved at the level of the procedures, which are currently too long and too expensive and not feasible easily for all laboratories. The procedures for obtaining reference values, if we follow the original documents, are complex, and that is the main reason that clinical chemists or diagnostic kit manufacturers have not used them systematically. There is clearly a need that scientific societies and international organizations propose practical recommendations: 1) Recommendations to describe methods linked to systematic error. * How to transfer reference limits from one laboratory to another laboratory using different methods? * Should we determine reference limits for each method? * How can we differentiate bias due to the populations from these due to the method? Clear collaborations with manufacturers involved in kits and diagnostic systems are needed. 2) Practical recommendations linked to the reference population. * How to select a homogeneous population? (Careful recommendations on the choice between healthy individuals, blood donors and individuals hospitalised for other diseases should be given.) * How to estimate ethnic differences? * How to define the exclusion and inclusion criteria according to quantity? * How to deal with the question of reference limits for unstable periods, aging or old people particularly, when the difference between aging and disease is very difficult to define? 3) Practical recommendations on the statistical methods to be used. * How to make a good choice of the interquartile interval? Should we use and present only the centiles 2.5 or 97.5, or on the contrary should we give other centiles in addition, for example 5, 10, 75, 80, 85, 90? 4) Practical recommendations linked to the use of the concept of the reference values. * How to make this concept more concrete and to have official definitions which are better understandable and not only abstract? * How to demonstrate the value of using simultaneously reference limits and decision limits, and what does each of these limits bring to results interpretation? * How to improve the presentation of the results? How to give more information on biological variability in the laboratory data, taking into account the scientific validity of their determination? Should we use new information techniques and new communication systems for reaching these objectives? The responses to all these questions could only be provided if there is a concerted effort at the international level. Practical recommendations should be given, which would be very useful for a better understanding and use of reference values by laboratory scientists and clinicians.

Entities:  

Mesh:

Year:  2000        PMID: 11028762     DOI: 10.1515/CCLM.2000.085

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  10 in total

1.  Foreword to Semen Analysis in 21st Century Medicine special issue in Asian Journal of Andrology.

Authors:  David J Handelsman; Trevor G Cooper
Journal:  Asian J Androl       Date:  2010-01       Impact factor: 3.285

Review 2.  A Review of Cutoffs for Nutritional Biomarkers.

Authors:  Ramkripa Raghavan; Fayrouz Sakr Ashour; Regan Bailey
Journal:  Adv Nutr       Date:  2016-01-15       Impact factor: 8.701

3.  Whether western normative laboratory values used for clinical diagnosis are applicable to Indian population? An overview on reference interval.

Authors:  T Malati
Journal:  Indian J Clin Biochem       Date:  2009-07-09

4.  Assessment of reference values for copper and zinc in blood serum of first and second lactating dairy cows.

Authors:  Markus Spolders; Martin Höltershinken; Ulrich Meyer; Jürgen Rehage; Gerhard Flachowsky
Journal:  Vet Med Int       Date:  2010-03-30

5.  An improved auto-generation system to obtain reference intervals for laboratory medicine.

Authors:  Hyung Hoi Kim; Hae Sook Hong; Shine Young Kim; Tung Tran; Ji Min Lee; Hwa Sun Kim; Hune Cho
Journal:  Healthc Inform Res       Date:  2010-03-31

6.  Reference range variation in haematological indices amongst five different age groups of less than one year in Islamabad, Pakistan.

Authors:  Kiran Tauseef Bukhari; Humaira Zafar
Journal:  Pak J Med Sci       Date:  2013-04       Impact factor: 1.088

Review 7.  Resampling methods in Microsoft Excel® for estimating reference intervals.

Authors:  Elvar Theodorsson
Journal:  Biochem Med (Zagreb)       Date:  2015-10-15       Impact factor: 2.313

Review 8.  Reference intervals: current status, recent developments and future considerations.

Authors:  Yesim Ozarda
Journal:  Biochem Med (Zagreb)       Date:  2016       Impact factor: 2.313

9.  Extracting physician group intelligence from electronic health records to support evidence based medicine.

Authors:  Griffin M Weber; Isaac S Kohane
Journal:  PLoS One       Date:  2013-05-29       Impact factor: 3.240

Review 10.  A Systematic Review and Pooled Analysis of Select Safety Parameters Among Normal Healthy Volunteers Taking Placebo in Phase 1 Clinical Trials.

Authors:  Tina C Young; Subasree Srinivasan; Marion L Vetter; Venkat Sethuraman; Zubin Bhagwagar; Ricardo Zwirtes; Premkumar Narasimhan; Tilda Chuang; Brendan J Smyth
Journal:  J Clin Pharmacol       Date:  2017-05-16       Impact factor: 3.126

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.