Novel quadrature birdcage coil for a vertical B(0) field open MRI system.

H Fujita1, W O Braum, M A Morich.   

Abstract

A birdcage coil possesses various intrinsic resonant modes. One of the modes produces sinusoidal current distribution around the rung elements of the birdcage and generates a highly uniform B(1) field in the transverse plane. Another mode is the end-ring resonant mode, in which there are no currents in the rungs of the birdcage, leaving the currents flowing in the top and bottom end-rings. Thus, this mode behaves like a "Helmholtz pair," producing a highly uniform B(1) field along the axis of the birdcage. By combining the sinusoidal resonant mode and the end-ring resonant mode at the same frequency, a quadrature birdcage coil for a vertical B(0) field is made possible. In particular, the coil dimension can be chosen such that the two end-ring loops behave as a Helmholtz pair, assuring the optimized B(1) field uniformity around the coil center region. The coil is well suited for a vertical B(0) MRI system, as both B(1) fields are perpendicular to the vertical B(0) field. To mimic a vertical B(0) field orientation, an existing horizontal bore MRI system was used with the RF coil oriented to simulate a "vertical" B(0) field. This is a report of the successful quadrature implementation of this novel birdcage coil.

Mesh:

Year:  2000        PMID: 11025520     DOI: 10.1002/1522-2594(200010)44:4<633::aid-mrm18>3.0.co;2-k

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  A fast and accurate simulator for the design of birdcage coils in MRI.

Authors:  Giulio Giovannetti; Luigi Landini; Maria Filomena Santarelli; Vincenzo Positano
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

2.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

3.  Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging.

Authors:  Yong Pang; Zhentian Xie; Ye Li; Duan Xu; Daniel Vigneron; Xiaoliang Zhang
Journal:  Materials (Basel)       Date:  2011-07-28       Impact factor: 3.623

4.  A Preliminary Study for Reference RF Coil at 11.7 T MRI: Based on Electromagnetic Field Simulation of Hybrid-BC RF Coil According to Diameter and Length at 3.0, 7.0 and 11.7 T.

Authors:  Jeung-Hoon Seo; Jun-Young Chung
Journal:  Sensors (Basel)       Date:  2022-02-15       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.