Literature DB >> 11021456

Low-conforming all-polyethylene tibial component not inferior to metal-backed component in cemented total knee arthroplasty: prospective, randomized radiostereometric analysis study of the AGC total knee prosthesis.

G Adalberth1, K G Nilsson, S Byström, K Kolstad, J Milbrink.   

Abstract

In a prospective, randomized study of 40 patients, the quality of fixation of cemented metal-backed versus all-polyethylene tibial components of the unconstrained anatomic graduated component total knee arthroplasty design was studied during 2 years using radiostereometric analysis (RSA). The shape, as well as the articulating geometry, of the implants was identical, as was the operative technique and the postoperative regimen. In this study, no negative consequences regarding the quality of fixation using an all-polyethylene tibial component with unconstrained articulating surfaces could be identified. In all aspects, the all-polyethylene tibial components displayed migration on par with, or sometimes lower than, their metal-backed counterparts. The rotations of the all-polyethylene components were equally low as for the metal-backed components, and maximum lift-off was significantly lower than for the metal-backed implants. We could not identify any collapse of the bone at the medial condyle or increased subsidence at the medial part of the tibia or increased rates of radiolucent lines in the knees with all-polyethylene components. All all-polyethylene implants seemed to be stable within the resolution of RSA between 1 and 2 years, a finding known to be of positive prognostic significance regarding future aseptic loosening.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11021456     DOI: 10.1054/arth.2000.8101

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  15 in total

Review 1.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

2.  All-polyethylene tibial components are not inferior to metal-backed tibial components in long-term follow-up of knee arthroplasties.

Authors:  Mustafa Yassin; Avraham Garti; Moshe Weissbrot; Uzi Ashkenazi; Muhammed Khatib; Dror Robinson
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-05-26

Review 3.  All-polyethylene tibial components are equal to metal-backed components: systematic review and meta-regression.

Authors:  Klaas Auke Nouta; Wiebe C Verra; Bart G Pijls; Jan W Schoones; Rob G H H Nelissen
Journal:  Clin Orthop Relat Res       Date:  2012-09-13       Impact factor: 4.176

Review 4.  Validity of published outcome data concerning Anatomic Graduated Component total knee arthroplasty: a structured literature review including arthroplasty register data.

Authors:  Reinhard Schuh; Gerald Dorninger; Mark Agreiter; Nikolaus Boehler; Gerold Labek
Journal:  Int Orthop       Date:  2011-04-13       Impact factor: 3.075

Review 5.  All-polyethylene versus metal-backed tibial component in total knee arthroplasty.

Authors:  Umile Giuseppe Longo; Mauro Ciuffreda; Valerio D'Andrea; Nicholas Mannering; Joel Locher; Vincenzo Denaro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-21       Impact factor: 4.342

Review 6.  Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties.

Authors:  Bart G Pijls; Edward R Valstar; Klaas-Auke Nouta; Josepha Wm Plevier; Marta Fiocco; Saskia Middeldorp; Rob Ghh Nelissen
Journal:  Acta Orthop       Date:  2012-11-09       Impact factor: 3.717

7.  Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty.

Authors:  Tao Cheng; Guoyou Zhang; Xianlong Zhang
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

Review 8.  Biomechanics of hyperflexion and kneeling before and after total knee arthroplasty.

Authors:  Thay Q Lee
Journal:  Clin Orthop Surg       Date:  2014-05-16

Review 9.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

10.  Monoblock versus modular polyethylene insert in uncemented total knee arthroplasty.

Authors:  Mikkel Rathsach Andersen; Nikolaj Winther; Thomas Lind; Henrik SchrøDer; Gunnar Flivik; Michael Mørk Petersen
Journal:  Acta Orthop       Date:  2016-09-20       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.