Literature DB >> 11020577

Active breathing control (ABC) for Hodgkin's disease: reduction in normal tissue irradiation with deep inspiration and implications for treatment.

J S Stromberg1, M B Sharpe, L H Kim, V R Kini, D A Jaffray, A A Martinez, J W Wong.   

Abstract

PURPOSE: Active breathing control (ABC) temporarily immobilizes breathing. This may allow a reduction in treatment margins. This planning study assesses normal tissue irradiation and reproducibility using ABC for Hodgkin's disease. METHODS AND MATERIALS: Five patients underwent CT scans using ABC obtained at the end of normal inspiration (NI), normal expiration (NE), and deep inspiration (DI). DI scans were repeated within the same session and 1-2 weeks later. To simulate mantle radiotherapy, a CTV1 was contoured encompassing the supraclavicular region, mediastinum, hila, and part of the heart. CTV2 was the same as CTV1 but included the whole heart. CTV3 encompassed the spleen and para-aortic lymph nodes. The planning target volume (PTV) was defined as CTV + 9 mm. PTVs were determined at NI, NE, and DI. A composite PTV (comp-PTV) based on the range of NI and NE PTVs was determined to represent the margin necessary for free breathing. Lung dose-mass histograms (DMH) for PTV1 and PTV2 and cardiac dose-volume histograms (DVH) for PTV3 were compared at the three different respiratory phases.
RESULTS: ABC was well-tolerated by all patients. DI breath-holds ranged from 34 to 45 s. DMHs determined for PTV1 revealed a median reduction in lung mass irradiated at DI of 12% (range, 9-24%; n = 5) compared with simulated free-breathing. PTV2 comparisons also showed a median reduction of 12% lung mass irradiated (range, 8-28%; n = 5). PTV3 analyses revealed the mean volume of heart irradiated decreased from 26% to 5% with deep inspiration (n = 5). Lung volume comparisons between intrasession and intersession DI studies revealed mean variations of 4%.
CONCLUSION: ABC is well tolerated and reproducible. Radiotherapy delivered at deep inspiration with ABC may decrease normal tissue irradiation in Hodgkin's disease patients.

Entities:  

Mesh:

Year:  2000        PMID: 11020577     DOI: 10.1016/s0360-3016(00)00681-7

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  14 in total

1.  [Ultrasound motion tracking for radiation therapy].

Authors:  J Jenne; J Schwaab
Journal:  Radiologe       Date:  2015-11       Impact factor: 0.635

2.  RapidArc combined with the active breathing coordinator provides an effective and accurate approach for the radiotherapy of hepatocellular carcinoma.

Authors:  G Z Gong; Y Yin; L G Xing; Y J Guo; T Liu; J Chen; J Lu; C Ma; T Sun; T Bai; G Zhang; R Wang
Journal:  Strahlenther Onkol       Date:  2012-02-08       Impact factor: 3.621

3.  Couch and multileaf collimator tracking: A clinical feasibility study for pancreas and liver treatment.

Authors:  Lei Zhang; Thomas LoSasso; Pengpeng Zhang; Margie Hunt; Gig Mageras; Grace Tang
Journal:  Med Phys       Date:  2020-09-11       Impact factor: 4.071

Review 4.  Evolution of the techniques of radiation therapy in the management of lymphoma.

Authors:  Richard T Hoppe
Journal:  Int J Clin Oncol       Date:  2013-04-11       Impact factor: 3.402

5.  Analysis of normal lung irradiation in radiosurgery treatments: a comparison of lung optimized treatment (LOT) on cyberknife, 4D target volume on helical tomotherapy, and DIBH on linear accelerator.

Authors:  Raghavendra Holla; D Khanna; V K Sathiya Narayanan; Deb Narayan Dutta
Journal:  Phys Eng Sci Med       Date:  2021-11-01

6.  Comparison between audio-only and audiovisual biofeedback for regulating patients' respiration during four-dimensional radiotherapy.

Authors:  Jesang Yu; Ji Hoon Choi; Sun Young Ma; Tae Sig Jeung; Sangwook Lim
Journal:  Radiat Oncol J       Date:  2015-09-30

7.  Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system.

Authors:  G S Mageras; E Yorke; K Rosenzweig; L Braban; E Keatley; E Ford; S A Leibel; C C Ling
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

8.  Visualisation of respiratory tumour motion and co-moving isodose lines in the context of respiratory gating, IMRT and flattening-filter-free beams.

Authors:  Yvonne Dzierma; Frank G Nuesken; Jochen Fleckenstein; Stephanie Kremp; Norbert P Licht; Christian Ruebe
Journal:  PLoS One       Date:  2013-01-10       Impact factor: 3.240

9.  First Steps Toward Ultrasound-Based Motion Compensation for Imaging and Therapy: Calibration with an Optical System and 4D PET Imaging.

Authors:  Julia Schwaab; Christopher Kurz; Cristina Sarti; André Bongers; Frédéric Schoenahl; Christoph Bert; Jürgen Debus; Katia Parodi; Jürgen Walter Jenne
Journal:  Front Oncol       Date:  2015-11-30       Impact factor: 6.244

10.  To gate or not to gate - dosimetric evaluation comparing Gated vs. ITV-based methodologies in stereotactic ablative body radiotherapy (SABR) treatment of lung cancer.

Authors:  Joshua Kim; Qixue Wu; Bo Zhao; Ning Wen; Munther Ajlouni; Benjamin Movsas; Indrin J Chetty
Journal:  Radiat Oncol       Date:  2016-09-22       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.