Literature DB >> 11018458

Unsteady stenosis flow prediction: a comparative study of non-Newtonian models with operator splitting scheme.

W L Siauw1, E Y Ng, J Mazumdar.   

Abstract

This paper presents a comparative study of non-Newtonian and Newtonian models of blood. A non-Newtonian incompressible 2-D Navier-Stokes (N-S) solver has been developed using Fasttalk language within the Fastflo environment. It is based on the method of operator splitting with artificial compressibility technique. The Power law and Casson models have been used as the constitutive equations for blood with a hematocrit of approximately 45%. These two non-Newtonian models and the Newtonian model are used to simulate unsteady flow through a hypothetical stenotic geometry over an aperiodic time interval of 1 s. Through comparison of the results of the three models, it was found that the wall shear stress (WSS) distribution over the time interval was comparable for both non-Newtonian models. The peak WSS for the Newtonian model had the lowest value. The peak wall shear stress gradient (WSSG) for the Power law was the highest, followed by the Casson and Newtonian models. Flow characteristics such as higher pressure drop across the stenosis, location and movement of vortex were similar in all three models. Non-Newtonian effects were most significant in the vicinity of the stenosis.

Entities:  

Mesh:

Year:  2000        PMID: 11018458     DOI: 10.1016/s1350-4533(00)00036-9

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  7 in total

1.  Timing and size of flow impingement in a giant intracranial aneurysm at the internal carotid artery.

Authors:  Liang-Der Jou; Michel E Mawad
Journal:  Med Biol Eng Comput       Date:  2011-01-06       Impact factor: 2.602

2.  Vertebral artery hypoplasia as an independent risk factor of posterior circulation atherosclerosis and ischemic stroke.

Authors:  Yasemin Dinç; Rifat Özpar; Büşra Emir; Bahattin Hakyemez; Mustafa Bakar
Journal:  Medicine (Baltimore)       Date:  2021-09-24       Impact factor: 1.817

3.  A comparative study of three speckle reducing methods for intima-media thickness ultrasound images.

Authors:  Mehravar Rafati; Masoud Arabfard; Mehrdad Rafati Rahimzadeh; Hasan Voshtani; Hassan Moladoust
Journal:  Iran Red Crescent Med J       Date:  2015-02-16       Impact factor: 0.611

Review 4.  High shear stress induces atherosclerotic vulnerable plaque formation through angiogenesis.

Authors:  Yi Wang; Juhui Qiu; Shisui Luo; Xiang Xie; Yiming Zheng; Kang Zhang; Zhiyi Ye; Wanqian Liu; Hans Gregersen; Guixue Wang
Journal:  Regen Biomater       Date:  2016-06-26

5.  Variations in pulsatile flow around stenosed microchannel depending on viscosity.

Authors:  Hyeonji Hong; Jae Min Song; Eunseop Yeom
Journal:  PLoS One       Date:  2019-01-24       Impact factor: 3.240

6.  The impact of vascular diameter ratio on hemodialysis maturation time: Evidence from data mining approaches and thermodynamics law.

Authors:  Mohammad Rezapour; Somayeh Taran; Mahmood Balin Parast; Morteza Khavanin Zadeh
Journal:  Med J Islam Repub Iran       Date:  2016-04-19

7.  Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

Authors:  M Y Abdollahzadeh Jamalabadi; Amin Ali Akbari Bidokhti; Hamid Khak Rah; Siavash Vaezi; Payam Hooshmand
Journal:  PLoS One       Date:  2016-12-12       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.