Literature DB >> 11016031

System performance of multislice spiral computed tomography.

T O Fuchs1, M Kachelriess, W A Kalender.   

Abstract

Multislice spiral CT offers many new possibilities for clinical CT imaging. Drastically increased scan speeds and z-resolution, respectively, as well as applications such as cardiac CT that have become feasible for the first time in routine clinical use. The concept of multiple simultaneously acquired slices yields image quality equivalent or better than single-slice spiral CT. Especially, there is no dependence on spiral pitch, neither with regard to noise nor to slice sensitivity. The reconstructed slice width can be chosen freely and retrospectively, which offers additional flexibility when evaluating optimal protocols for various kinds of examinations. Three-dimensional isotropic resolution can be achieved routinely with examinations fast enough to scan in a single breath hold (Fig. 9). Without any drawbacks in image quality, MSCT in combination with online tube current modulation can reduce patient dose. In some body regions, dose is decreased to 50% compared to a scan with constant tube current. One of the most promising new applications is the dedicated ECG-gated cardiac interpolation 180 degrees MCI, which allows four-dimensional (4-D) imaging of the heart. The complete beating heart can be reconstructed in well-defined phases of the heart cycle, thereby adding high temporal resolution to isotropic 3-D spatial resolution (for more examples refer to http://www.imp.uni-erlangen.de/e/research/cardio/).

Entities:  

Mesh:

Year:  2000        PMID: 11016031     DOI: 10.1109/51.870232

Source DB:  PubMed          Journal:  IEEE Eng Med Biol Mag        ISSN: 0739-5175


  5 in total

1.  Similarity enhancement for automatic segmentation of cardiac structures in computed tomography volumes.

Authors:  Miguel Vera; Antonio Bravo; Mireille Garreau; Rubén Medina
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

2.  Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey.

Authors:  G Brix; H D Nagel; G Stamm; R Veit; U Lechel; J Griebel; M Galanski
Journal:  Eur Radiol       Date:  2003-04-10       Impact factor: 5.315

3.  MSCT versus CBCT: evaluation of high-resolution acquisition modes for dento-maxillary and skull-base imaging.

Authors:  Jean-Philippe Dillenseger; Jean-François Matern; Catherine-Isabelle Gros; Fabien Bornert; Christian Goetz; Jean-Marie Le Minor; André Constantinesco; Philippe Choquet
Journal:  Eur Radiol       Date:  2014-09-24       Impact factor: 5.315

4.  Multidetector computed tomography of the head in acute stroke: predictive value of different patterns of the dense artery sign revealed by maximum intensity projection reformations for location and extent of the infarcted area.

Authors:  Davide Gadda; Letizia Vannucchi; Franco Niccolai; Anna T Neri; Luca Carmignani; Patrizio Pacini
Journal:  Eur Radiol       Date:  2005-07-30       Impact factor: 5.315

5.  Traumatic lesions of corpus callosum: early multidetector CT findings.

Authors:  Davide Gadda; Luca Carmignani; Letizia Vannucchi; Alessandra Bindi
Journal:  Neuroradiology       Date:  2004-10       Impact factor: 2.804

  5 in total