Literature DB >> 11015505

Video recording as a means of evaluating neonatal resuscitation performance.

D N Carbine1, N N Finer, E Knodel, W Rich.   

Abstract

OBJECTIVE: To determine the compliance to Neonatal Resuscitation Program (NRP) guidelines in our institution, by the use of videotaped newborn resuscitations.
BACKGROUND: NRP is the standard of care for newborn resuscitation. The application of NRP guidelines and resuscitation skills in actual clinical settings is undocumented. DESIGN/
METHODS: A video recorder, mounted to the radiant warmer in the main obstetrical operating room, was used to record all high-risk resuscitations. All members of the resuscitation team were NRP-certified. The videotapes were reviewed within 14 days of the resuscitation and then erased. This ongoing review was approved as a quality assurance (QA) project ensuring confidentiality under California law. The first 100 resuscitations were evaluated to assess NRP compliance. Each step in the resuscitation (positioning, oxygen delivery, ventilation, chest compressions, intubation, and medication) was graded. A score was devised, with 2 points being awarded for every correct decision and proper procedure, 1 point for delayed interventions or inadequate technique, and zero points for indicated procedures that were omitted or for interventions that were not indicated. The total points were divided by the total possible points for that patient. The scores for the first 25 resuscitations (group 1) and the last 25 resuscitations (group 2) were compared.
RESULTS: Fifty-four percent of the 100 resuscitations had deviations from the NRP guidelines. Ten percent received overly aggressive stimulation and 22% had poor suction technique. Of the 78 infants given oxygen, this decision was considered incorrect in 15% and the delivery technique was poor in 10% of the infants given oxygen. Of those requiring mask ventilation (n = 18), 24% had poor chest expansion, 11% used an incorrect rate, and 17% had inadequate reevaluation. Twelve infants were intubated; only 7 were successfully intubated on the first attempt and only 4 were intubated in <20 seconds. The longest intubation attempt was 50 seconds. Naloxone was given to 2 patients. One was breathing spontaneously with a heart rate >100. Resuscitations receiving a perfect evaluation score were more likely to occur in infants needing less intervention. The level of resuscitation required for groups 1 and 2 were statistically similar. There was no difference in resuscitation scores between the 2 groups. Only the inappropriate use of deep suctioning improved, with 8 of 25 events in group 1, and 0 of 25 in group 2.
CONCLUSIONS: We have found a significant number of deviations from the NRP guidelines. Video recording of actual clinical practice is a useful QA tool for monitoring the conduct of newborn resuscitation. We are now conducting repeat video assessments of individual NRP providers to determine whether there is improved performance.

Entities:  

Mesh:

Year:  2000        PMID: 11015505     DOI: 10.1542/peds.106.4.654

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  43 in total

1.  Video techniques and data compared with observation in emergency trauma care.

Authors:  C F Mackenzie; Y Xiao
Journal:  Qual Saf Health Care       Date:  2003-12

2.  Comparison of training in neonatal resuscitation using self inflating bag and T-piece resuscitator.

Authors:  S S Mathai; K M Adhikari; A Rajeev
Journal:  Med J Armed Forces India       Date:  2014-08-15

Review 3.  Tackling Quality Improvement in the Delivery Room.

Authors:  Wannasiri Lapcharoensap; Henry C Lee
Journal:  Clin Perinatol       Date:  2017-07-14       Impact factor: 3.430

4.  Rapid sequence intubation for pediatric emergency patients: higher frequency of failed attempts and adverse effects found by video review.

Authors:  Benjamin T Kerrey; Andrea S Rinderknecht; Gary L Geis; Lise E Nigrovic; Matthew R Mittiga
Journal:  Ann Emerg Med       Date:  2012-03-15       Impact factor: 5.721

5.  Pediatrics residents' preparedness for neonatal resuscitation assessed using high-fidelity simulation.

Authors:  Leandro Cordero; Brandon J Hart; Rene Hardin; John D Mahan; Peter J Giannone; Craig A Nankervis
Journal:  J Grad Med Educ       Date:  2013-09

6.  Does simulation booster impact retention of resuscitation procedural skills and teamwork?

Authors:  J Bender; K Kennally; R Shields; F Overly
Journal:  J Perinatol       Date:  2014-04-24       Impact factor: 2.521

7.  Resuscitator's perceptions and time for corrective ventilation steps during neonatal resuscitation.

Authors:  Vinay Sharma; Satyan Lakshminrusimha; Vivien Carrion; Bobby Mathew
Journal:  Resuscitation       Date:  2015-03-20       Impact factor: 5.262

8.  Neonatal Resuscitation with an Intact Cord: A Randomized Clinical Trial.

Authors:  Anup Katheria; Debra Poeltler; Jayson Durham; Jane Steen; Wade Rich; Kathy Arnell; Mauricio Maldonado; Larry Cousins; Neil Finer
Journal:  J Pediatr       Date:  2016-08-26       Impact factor: 4.406

9.  Quality Improvement Project to Decrease Delivery Room Intubations in Preterm Infants.

Authors:  Venkatakrishna Kakkilaya; Ihab Jubran; Vaishali Mashruwala; Emma Ramon; Valerie N Simcik; Marjory Marshall; L Steven Brown; Mambarambath A Jaleel; Vishal S Kapadia
Journal:  Pediatrics       Date:  2019-01-02       Impact factor: 7.124

10.  Impact of flow disruptions in the delivery room.

Authors:  Heidi M Herrick; Scott Lorch; Jesse Y Hsu; Kenneth Catchpole; Elizabeth E Foglia
Journal:  Resuscitation       Date:  2020-03-16       Impact factor: 5.262

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.