A clinical evaluation of the Codman MicroSensor for intracranial pressure monitoring.

D F Signorini1, A Shad, I R Piper, P F Statham.   

Abstract

The strain-gauge Codman MicroSensor intracranial pressure (ICP) transducer has shown consistently good laboratory performance. To assess the practical performance of the system in patients following acute brain injury, 10 patients were fitted with a MicroSensor and a second ICP monitor. In five cases this was a fibre-optic transducer and in five cases an intraventricular fluid-filled device. Paired ICP values were recorded every 5 min. ICP values ranged from 0 to 31 mmHg. Altman-Bland plots showed that individual readings could differ by as much as 9 mmHg. Further analysis showed that much of this disagreement could be explained by a constant offset on each occasion. Comparison traces of ICP in individual patients show high agreement in timing and size of changes. The unexplained constant offset leads to uncertainty about the true ICP. Treatment decisions are often based upon absolute levels of ICP and patient care may therefore differ depending upon the monitor used.

Entities:  

Mesh:

Year:  1998        PMID: 11013684     DOI: 10.1080/02688699845032

Source DB:  PubMed          Journal:  Br J Neurosurg        ISSN: 0268-8697            Impact factor:   1.596


  6 in total

1.  An evaluation and comparison of intraventricular, intraparenchymal, and fluid-coupled techniques for intracranial pressure monitoring in patients with severe traumatic brain injury.

Authors:  John Vender; Jennifer Waller; Krishnan Dhandapani; Dennis McDonnell
Journal:  J Clin Monit Comput       Date:  2011-09-22       Impact factor: 2.502

Review 2.  Implantable Sensors for Regenerative Medicine.

Authors:  Brett S Klosterhoff; Melissa Tsang; Didi She; Keat Ghee Ong; Mark G Allen; Nick J Willett; Robert E Guldberg
Journal:  J Biomech Eng       Date:  2017-02-01       Impact factor: 2.097

3.  The baseline pressure of intracranial pressure (ICP) sensors can be altered by electrostatic discharges.

Authors:  Per K Eide; André Bakken
Journal:  Biomed Eng Online       Date:  2011-08-22       Impact factor: 2.819

Review 4.  Accuracy of intracranial pressure monitoring: systematic review and meta-analysis.

Authors:  Lucia Zacchetti; Sandra Magnoni; Federica Di Corte; Elisa R Zanier; Nino Stocchetti
Journal:  Crit Care       Date:  2015-12-02       Impact factor: 9.097

5.  An intracranial pressure-derived index monitored simultaneously from two separate sensors in patients with cerebral bleeds: comparison of findings.

Authors:  Per Kristian Eide; Wilhelm Sorteberg
Journal:  Biomed Eng Online       Date:  2013-02-13       Impact factor: 2.819

6.  Simultaneous monitoring of static and dynamic intracranial pressure parameters from two separate sensors in patients with cerebral bleeds: comparison of findings.

Authors:  Per Kristian Eide; Sverre Holm; Wilhelm Sorteberg
Journal:  Biomed Eng Online       Date:  2012-09-07       Impact factor: 2.819

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.