Literature DB >> 11013194

Comparison of artificial eye amplitudes with acrylic and hydroxyapatite spherical enucleation implants.

T P Colen1, D A Paridaens, H G Lemij, M P Mourits, W A van Den Bosch.   

Abstract

PURPOSE: To compare artificial eye amplitudes in patients who randomly received either a hydroxyapatite or an acrylic, scleral-covered spherical implant after enucleation.
DESIGN: Randomized, controlled trial. PARTICIPANTS: Thirty-four consecutive patients who underwent enucleation because of an intraocular melanoma and 21 healthy control participants from the hospital staff.
METHODS: Eligible patients randomly received a hydroxyapatite or an acrylic, scleral-covered spherical orbital implant. Fourteen patients were fitted with a hydroxyapatite implant, and 16 were fitted with an acrylic implant. We measured horizontal and vertical saccadic amplitudes of both the artificial eye and the healthy eye. Measurements were performed with the magnetic search coils technique. Saccadic amplitudes of the artificial eye were compared with the healthy eye of the patient. The amplitudes of the healthy eyes were compared with saccadic amplitudes of control participants. The interval from surgery to measurements was at least 3 months in all patients. Saccadic gain (artificial eye and eye amplitude divided by target amplitude) and saccadic symmetry (artificial eye amplitude divided by healthy eye amplitude) were calculated. MAIN OUTCOME MEASURES: Saccadic gain and saccadic symmetry.
RESULTS: The gain in the healthy eyes of the patients was comparable with the gain of the control eyes. Saccadic symmetry was 1.0 in control participants. In patients, it was 0.334 in horizontal saccades and 0.577 in vertical saccades. However, saccadic symmetry did not differ significantly between the acrylic group and the hydroxyapatite group (P: > 0.1 for any saccadic direction). Equivalence was detectable with a power more than 90% for horizontal saccades and more than 80% for vertical saccades. Curvilinearity was rejected for both patient groups and for all saccadic directions (P: > 0.5).
CONCLUSIONS: When no motility peg is placed, acrylic and hydroxyapatite spherical implants yield comparable saccadic amplitudes of the artificial eye. Artificial eye amplitudes were markedly more restricted horizontally than vertically. In all saccadic directions, the relation between target amplitude and artificial eye amplitude was linear.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11013194     DOI: 10.1016/s0161-6420(00)00348-1

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  9 in total

1.  Unexpected ¹⁸F-FDG uptake in an ocular prosthesis.

Authors:  Elgin Ozkan; Mine Araz; Cigdem Soydal; Gulseren Aras
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-06-16       Impact factor: 9.236

2.  [Porous orbital implants].

Authors:  B Cleres; H W Meyer-Rüsenberg
Journal:  Ophthalmologe       Date:  2014-06       Impact factor: 1.059

Review 3.  Integrated versus non-integrated orbital implants for treating anophthalmic sockets.

Authors:  Silvana Schellini; Regina El Dib; Leandro Re Silva; Joyce G Farat; Yuqing Zhang; Eliane C Jorge
Journal:  Cochrane Database Syst Rev       Date:  2016-11-07

4.  UK national survey of enucleation, evisceration and orbital implant trends.

Authors:  P Viswanathan; Mandeep S Sagoo; Jane M Olver
Journal:  Br J Ophthalmol       Date:  2006-12-06       Impact factor: 4.638

5.  Long-term Surgical Outcomes of the Multi-purpose Conical Porous Synthetic Orbital Implant.

Authors:  Min-Ji Kang; Su-Kyung Jung; Won-Kyung Cho; Ji-Sun Paik; Suk-Woo Yang
Journal:  Korean J Ophthalmol       Date:  2015-09-22

6.  A Digital Microscreen for the Enhanced Appearance of Ocular Prosthetic Motility (an American Ophthalmological Society Thesis).

Authors:  Jeremiah P Tao; Emily S Charlson; Yinheng Zhu; Zonglin Guo; Wanli Chen; Xun Zhan; Hongjian Shi; Ian G Harris
Journal:  Am J Ophthalmol       Date:  2021-04-11       Impact factor: 5.488

7.  A Multidisciplinary Approach for Rehabilitation of Enucleated Sockets: Ocular Implants with Custom Ocular Prosthesis.

Authors:  Minati Choudhury; Fathima Banu; Shanmuganathan Natarajan; Anand Kumar; Padmanabhan Tv
Journal:  Cureus       Date:  2018-02-16

8.  Association between Subjective and Objective Assessment of Enucleation Outcome Depending on the Presence of an Orbital Implant in Patients with Uveal Melanoma.

Authors:  Weronika Pociej-Marciak; Bożena Romanowska-Dixon; Katarzyna Żuber-Łaskawiec; Mojca Globočnik Petrovič; Izabella Karska-Basta
Journal:  J Clin Med       Date:  2022-04-12       Impact factor: 4.964

9.  Worldwide enucleation techniques and materials for treatment of retinoblastoma: an international survey.

Authors:  Daphne L Mourits; Dyonne T Hartong; Machteld I Bosscha; Roel J H M Kloos; Annette C Moll
Journal:  PLoS One       Date:  2015-03-13       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.