Literature DB >> 11013179

Accuracy of clinical estimates of intraocular pressure in Chinese eyes.

P J Foster1, J S Wong, E Wong, F G Chen, D Machin, P T Chew.   

Abstract

PURPOSE: To investigate the validity of clinical estimates of intraocular pressure (IOP) in Chinese people.
DESIGN: Prospective, cross-sectional, hospital-based in vivo study. PARTICIPANTS: Twenty-three ethnic Chinese adults (aged 35-82 years) undergoing routine phacoemulsification surgery were examined. TESTING: "True" IOP was measured with a solid-state hemodynamic monitor through a cannula in the anterior chamber. IOP was set successively to 10, 20, and 30 mmHg in each subject, using a reservoir of balanced salt solution. Intraocular pressure was simultaneously estimated by use of a hand-held applanation tonometer (Perkin's) and a Tono-Pen. The association between ocular biometric variables and measurement error was examined. MAIN OUTCOME MEASURES: The median of three readings at each IOP level was taken as the IOP estimate of each instrument. Measurement error was calculated as the mean difference (tonometer minus direct measurement).
RESULTS: The error for the hand-held applanation tonometer was -1.6, -4.3 and -5.7 at 10, 20, and 30 mmHg, respectively. For the Tono-Pen the measurement error was +0.4, -2.0, and -4.1 at 10, 20, and 30 mmHg, respectively. We could identify no association between measurement error and corneal thickness or curvature, anterior chamber depth, or axial length.
CONCLUSIONS: The applanation tonometer and Tono-Pen underestimate the true IOP in Chinese eyes. Error increases as true IOP increases. These tonometers do not give an accurate estimate of IOP in East Asians.

Entities:  

Mesh:

Year:  2000        PMID: 11013179     DOI: 10.1016/s0161-6420(00)00343-2

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  12 in total

Review 1.  [Glaucoma diagnostics and corneal thickness].

Authors:  J von Eicken; M Kohlhaas; H Höh
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

2.  The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.

Authors:  P-A Tonnu; T Ho; T Newson; A El Sheikh; K Sharma; E White; C Bunce; D Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

3.  A comparison of four methods of tonometry: method agreement and interobserver variability.

Authors:  P-A Tonnu; T Ho; K Sharma; E White; C Bunce; D Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

4.  Central corneal thickness in southern Egypt.

Authors:  Engy Mohamed Mostafa
Journal:  Int Ophthalmol       Date:  2013-11-22       Impact factor: 2.031

5.  Clinical evaluation of multiparameter correction equations for Goldmann applanation tonometry.

Authors:  P G Davey; A Elsheikh; D F Garway-Heath
Journal:  Eye (Lond)       Date:  2013-03-15       Impact factor: 3.775

6.  Changes of corneal central thickness of aphakia following congenital cataract surgery under the first six months of life.

Authors:  Wei Xiao; Xiao-Fang Liang; Jia-Jun Sun
Journal:  Int J Ophthalmol       Date:  2011-02-18       Impact factor: 1.779

Review 7.  Neuroprotection for treatment of glaucoma in adults.

Authors:  Dayse F Sena; Kristina Lindsley
Journal:  Cochrane Database Syst Rev       Date:  2017-01-25

Review 8.  Neuroprotection for treatment of glaucoma in adults.

Authors:  Dayse F Sena; Kristina Lindsley
Journal:  Cochrane Database Syst Rev       Date:  2013-02-28

9.  Central corneal thickness and intraocular pressure in the Cameroonian nonglaucomatous population.

Authors:  André Omgbwa Eballe; Godefroy Koki; Augustin Ellong; Didier Owono; Emilienne Epée; Lucienne Assumpta Bella; Côme Ebana Mvogo; Jeanne Mayouego Kouam
Journal:  Clin Ophthalmol       Date:  2010-07-30

10.  Causes of low vision and blindness in rural Indonesia.

Authors:  S-M Saw; R Husain; G M Gazzard; D Koh; D Widjaja; D T H Tan
Journal:  Br J Ophthalmol       Date:  2003-09       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.